新型热处理镍钛系统根管预备后牙本质微裂纹的微CT评价

Micro-computed Tomographic Evaluation of Dentinal Microcrack Formation after Using New Heat-treated Nickel-titanium Systems.
PubMed 文献 · J Endod · 2017-07-27

本研究采用微计算机断层扫描(micro-CT)评估HyFlex CM、HyFlex EDM、Vortex Blue和TRUShape四种镍钛系统预备下颌切牙直根管后牙本质微裂纹的发生频率。结论认为这四种系统在直根管中未诱导新的牙本质微裂纹。

要点

  • HyFlex CM、HyFlex EDM、Vortex Blue和TRUShape预备直根管后未产生新牙本质微裂纹。
  • 研究采用配对设计,预备前后micro-CT图像对比筛查牙本质缺陷。
  • 下颌切牙直根管中牙本质缺陷发生率为12.31%。

核心结论

  • HyFlex CM、HyFlex EDM、Vortex Blue和TRUShape系统预备下颌切牙直根管未诱导新牙本质微裂纹形成。

主要发现

  • 测试系统根管预备后未观察到新微裂纹。

临床怎么用

  • 使用HyFlex CM、HyFlex EDM、Vortex Blue或TRUShape预备直根管时,无需担心诱导新牙本质微裂纹。

局限性

  • 仅评估下颌切牙直根管,未涉及弯曲根管或其他牙位。
  • 离体研究,临床转化需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with HyFlex CM (Coltène/Whaledent, Altstätten, Switzerland), HyFlex EDM (Coltène/Whaledent), Vortex Blue (Dentsply Tulsa Dental Specialties, Tulsa, OK), and TRUShape (Dentsply Tulsa Dental Specialties) systems using micro-computed tomographic (micro-CT) analysis. METHODS: Forty human mandibular incisors with 1 and straight root canals were randomly assigned to 4 experimental groups (n = 10) and 1 control group for root canal preparation: group 1, HyFlex CM; group 2, HyFlex EDM; group 3, Vortex Blue; and group 4, TRUShape. The specimens were scanned using high-resolution micro-CT imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. The number of microcracks was determined as a percentage for each group. RESULTS: Before and after canal preparation, 36,152 cross-sectional images were examined. Four thousand four hundred fifty-two (12.31%) dentinal defects were observed. No new microcracks were observed after root canal instrumentation with the tested systems. CONCLUSIONS: Root canal preparation with the HyFlex CM, HyFlex EDM, Vortex Blue, and TRUShape systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular incisors.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Bayram HM, Bayram E, Ocak M, et al. Micro-computed Tomographic Evaluation of Dentinal Microcrack Formation after Using New Heat-treated Nickel-titanium Systems. J Endod. 2017. PMID: 28756963. doi:10.1016/j.joen.2017.05.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。