镍钛旋转器械在根管治疗与再治疗中折断的5年回顾性研究
结果显示再治疗病例的器械折断率(2.96%)显著高于初次治疗(0.74%)(P < 0.001),总体发生率为1.41%。折断主要发生于重度弯曲根管的根尖三分之一处,且多为小号器械(20号和25号)。
要点
- 再治疗时K3镍钛器械折断率(2.96%)显著高于初次根管治疗(0.74%)。
- 56.6%的器械折断发生于重度弯曲根管,85.7%位于根尖三分之一。
- 折断器械主要为20号(59.9%)和25号(25.27%)小号锉。
核心结论
- K3镍钛旋转器械在根管再治疗中的折断发生率显著高于初次根管治疗,且主要发生于小号器械和根尖三分之一处。
主要发现
- 再治疗病例的器械折断发生率为2.96%,初次根管治疗为0.74%,总体发生率为1.41%(P < 0.001)。
- 上颌磨牙(1.68%)和下颌磨牙(1.35%)有更高的折断趋势。
- 56.6%的折断器械发生于重度弯曲根管(>25°)。
- 折断部位最常见于根尖三分之一(85.7%),其次为根中三分之一(13.2%)和冠部三分之一(1.1%)。
- 折断器械的号数主要为20号(59.9%)和25号(25.27%)。
临床怎么用
- 在根管再治疗中应警惕K3镍钛旋转器械的折断风险,尤其是在重度弯曲根管的根尖区域使用小号器械时。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate retrospectively the incidence of K3 nickel titanium rotary instrument fracture in referred cases during root canal treatment and re-treatment. METHODOLOGY: Clinical and radiographic reports of 12 867 endodontic cases treated at the King Abdulaziz medical city between January 2010 and November 2015 were reviewed to obtain information on intracanal fractured instruments with respect to the treatment performed, tooth type and the size and at what level the instrument fractured (coronal, middle or apical). The degree of canal curvature was classified into mild (<10° ), moderate (10-25° ) or severe (>25° ). Logistic regression was used to test the incidence of instrument fracture in relation to the root canal treatment performed and tooth type. Chi-square tests were used to analyse the fracture incidence in the treated teeth in respect to fracture level and fractured file diameter. The level of significance was set at 0.05. RESULTS: Root canal treatment was performed on 8946 cases, whilst re-treatment was performed on 3921 cases. The fracture incidence was higher during re-treatment cases (2.96%) than in primary root canal treatment (0.74%) (P < 0.001) with a 1.41% incidence overall. There was a trend for more fractures in maxillary (1.68%) and mandibular (1.35%) molar teeth. Moreover, 56.6% of the fractured instruments occurred in severely curved canals, and the apical third of the root canal was the most common site for instrument fracture (85.7%), followed by middle (13.2%), and coronal (1.1%) thirds, mostly with file sizes 20 and 25 (59.9% and 25.27%, respectively). CONCLUSION: The fracture incidence of K3 instruments was significantly greater during root canal re-treatment than root canal treatment, mainly with small instruments and in the apical third of the canals.
引用
- Alfouzan K, Jamleh A. Fracture of nickel titanium rotary instrument during root canal treatment and re-treatment: a 5-year retrospective study. Int Endod J. 2017. PMID: 28796346. doi:10.1111/iej.12826
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。