文献速递牙体牙髓病

不同技术填充3D打印树脂牙模拟C形根管的评价

Evaluation of Different Techniques for Filling Simulated C-shaped Canals of 3-dimensional Printed Resin Teeth.
PubMed 文献 · J Endod · 2017-07-27

本研究利用3D打印技术制作80个C1型根管下颌磨牙树脂复制品,比较四种根管充填技术(GuttaCore、连续波充填、冷侧压、GuttaFlow Bioseal)的充填效果。结果显示在根尖2mm处,冷侧压和冷注射充填组的空隙率显著低于热牙胶充填组(P < .05)。结论认为在C1根管构型的根尖部分,冷侧压和冷注射充填技术比热牙胶充填技术更成功。

要点

  • 冷侧压和冷注射充填在根尖2mm处空隙显著少于热牙胶充填。
  • 连续波充填组在2mm处空隙率最高、牙胶百分比最低。
  • 全区域冷侧压和冷注射组牙胶少、封闭剂多,组间无差异。

核心结论

  • 在C1根管构型的根尖部分,冷侧压和冷注射充填技术比热牙胶充填技术更成功。

研究设计与样本

  • 利用锥形束CT选取C1型根管下颌磨牙,经ProTaper Universal和手用锉预备后micro-CT扫描,3D打印80个复制品,随机分4组(n=20)分别用GuttaCore、连续波充填、冷侧压或GuttaFlow Bioseal充填;在距根尖2、4、6、8、10 mm处切片,32倍立体显微镜下测量牙胶、封闭剂和空隙面积百分比;采用多因素方差分析和Tukey HSD检验(P < .05)。

主要发现

  • 连续波充填组在2 mm切片处空隙平均百分比最高、牙胶平均百分比最低(P < .05)。
  • 2 mm处组间比较:冷侧压和GuttaFlow Bioseal组空隙显著少于连续波充填和GuttaCore组(P < .05)。
  • 全区域比较:冷侧压和GuttaFlow Bioseal组牙胶百分比显著低于其他组、封闭剂百分比显著高于其他组(P < .05),且两组间无显著差异(P > .05)。

临床怎么用

  • 对于C1型根管构型,根尖部分可优先考虑冷侧压或冷注射充填技术。

局限性

  • 研究使用3D打印树脂复制品,非真实牙体,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study was to compare the ability of different root canal filling methods on the C1 root canal anatomy using 3-dimensional (3D) printer technology. METHODS: Mandibular molars were scanned with cone-beam computed tomographic (CBCT) imaging. A mandibular molar tooth with a C1 root canal configuration was selected according to images obtained from CBCT technology. The root canals were shaped with ProTaper Universal rotary instruments (Dentsply Maillefer, Ballaigues, Switzerland) and hand files. After the root canal shaping procedure, the tooth was scanned with micro-computed tomographic imaging, and 80 replicas of the tooth were produced with a 3D printer. Replicas were assigned into 4 groups (n = 20) and were filled using one of the following techniques: a core carrier system (GuttaCore [GC]; Dentsply Tulsa Dental Specialties, Tulsa, OK), a continuous wave obturation system (Elements Free [CW]; Kerr/SybronEndo, Orange, CA), a cold lateral compaction technique (CLC), or the injectable cold filling method (GuttaFlow Bioseal [GFB]; Coltène/Whaledent AG, Altstatten, Switzerland). All specimens were sectioned horizontally at 2, 4, 6, 8, and 10 mm from the apices of the specimens. The sections were examined at 32× magnification under a stereomicroscope, and the percentage areas of gutta-percha, sealer, and voids were measured. Statistical analysis of data was performed using multivariate analysis of variance and Tukey honestly significant difference tests (P < .05). RESULTS: The CW group had the highest mean percentages for void and the least mean percentages for gutta-percha at 2-mm sections (P < .05). A pairwise comparison between the groups showed significantly less void in the CLC and GFB groups and more void in the CW and GC groups at 2 mm (P < .05). In the total area, the CLC and GFB groups showed a significantly lower percentage of gutta-percha and more sealer compared with the other groups (P < .05), and there was no significant difference between the CLC and GFB groups (P > .05). CONCLUSIONS: At the apical part of the canal, the cold lateral compaction and cold injectable filling techniques were more successful compared with the warm gutta-percha filling techniques in C1 root canal configuration.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Gok T, Capar ID, Akcay I, et al. Evaluation of Different Techniques for Filling Simulated C-shaped Canals of 3-dimensional Printed Resin Teeth. J Endod. 2017. PMID: 28756962. doi:10.1016/j.joen.2017.04.029