不同高分辨率锥形束CT成像协议检测根管治疗后牙根不完全折裂
本研究比较两种高分辨率CBCT成像协议(HI-STD与HI-HI)对根管治疗后单根牙不完全根折的诊断价值。两种协议准确度分别为0.90和0.93,灵敏度均为0.97,HI-HI阳性预测值和ROC曲线下面积略高。结论:两种协议均具高准确度,推荐使用HI-STD以减少辐射剂量。
要点
- HI-STD与HI-HI协议诊断不完全根折的准确度分别为0.90和0.93。
- 两种协议灵敏度均为0.97,HI-HI阳性预测值和ROC曲线下面积略高。
- 推荐使用HI-STD协议,因其在保持高准确度的同时减少辐射剂量。
核心结论
- 两种高分辨率CBCT成像协议对根管治疗后牙不完全根折均具有高诊断准确度。
- HI-STD协议应被推荐使用,以减少辐射剂量。
研究设计与样本
- 使用PreXion 3D CBCT设备,采用HI-STD(19秒,512幅基础图像)和HI-HI(37秒,1024幅基础图像)两种协议扫描。
- 由3名口腔放射医师利用多平面重建评估所有图像,计算诊断试验和ROC曲线。
主要发现
- HI-STD和HI-HI协议的准确度分别为0.90和0.93。
- 两种协议的灵敏度均为0.97。
- HI-HI协议显示更高的阳性预测值和略高的ROC曲线下面积。
关键数值与推荐
- HI-STD协议准确度0.90,灵敏度0.97。
- HI-HI协议准确度0.93,灵敏度0.97。
临床怎么用
- 临床上检测根管治疗后牙不完全根折时,可优先选择HI-STD协议以降低辐射剂量。
- 当需要更高阳性预测值时,可考虑HI-HI协议。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to compare different high-resolution cone-beam computed tomographic (CBCT) imaging protocols in the diagnosis of incomplete root fractures of endodontically treated teeth. METHODS: Twenty single-rooted human teeth were endodontically treated, and an incomplete root fracture was induced. The teeth were scanned with the CBCT unit PreXion 3D (Teracom, San Mateo, CA) operating at 2 different protocols: high resolution/standard (HI-STD) (19 seconds and 512 basis images) and high resolution/high density (HI-HI) (37 seconds and 1024 basis images). Three oral radiologists evaluated all images using multiplanar reconstructions. The diagnostic tests and the receiver operating characteristic (ROC) curve were calculated. RESULTS: The HI-STD and HI-HI protocols presented an accuracy of 0.90 and 0.93, respectively, and both protocols had a sensitivity of 0.97. The HI-HI protocol showed a higher positive predictive value and slightly higher areas under the ROC curve. CONCLUSIONS: Both high-resolution imaging protocols presented high accuracy in the detection of incomplete root fracture of endodontically teeth. Thus, the HI-STD protocol should be indicated this reduces the radiation dose.
引用
- Wanderley VA, Neves FS, Nascimento MCC, et al. Detection of Incomplete Root Fractures in Endodontically Treated Teeth Using Different High-resolution Cone-beam Computed Tomographic Imaging Protocols. J Endod. 2017. PMID: 28735791. doi:10.1016/j.joen.2017.05.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。