文献速递牙体牙髓病

不同运动方式对K3XF器械根管预备时冲洗液和碎屑根尖挤出影响

Influence of Different Kinematics on Apical Extrusion of Irrigant and Debris during Canal Preparation Using K3XF Instruments.
PubMed 文献 · J Endod · 2017-07-20

这项体外研究将80颗离体下颌前磨牙随机分4组,比较手用K锉逐步后退法与K3XF三种运动方式(往复、自适应、连续旋转)根尖挤出碎屑和冲洗液的量。手用器械碎屑挤出显著多于K3XF各组(P<.05),K3XF不同运动方式间碎屑挤出无显著差异(P>.05),冲洗液挤出各组均无显著差异(P>.05)。

要点

  • 手用K锉逐步后退法根尖碎屑挤出显著多于K3XF器械。
  • K3XF往复运动碎屑挤出均值最高、连续旋转最低,但差异无统计学意义。
  • 各器械运动方式均存在根尖碎屑和冲洗液挤出,冲洗液量组间无差异。

核心结论

  • 手用器械根尖碎屑挤出多于K3XF器械的不同运动方式。
  • 所有器械运动方式均伴有根尖碎屑和冲洗液挤出。

研究设计与样本

  • 体外研究,选取80颗离体下颌前磨牙随机分为4组,每组20颗。
  • 比较手用K型不锈钢锉逐步后退法与K3XF的往复、自适应、连续旋转三种运动方式。
  • 以双蒸水为冲洗液,用预称重Eppendorf管收集根尖挤出碎屑,用塑料胰岛素注射器从引流套管收集冲洗液并记录体积。
  • 液体完全蒸发后测定每个样本挤出碎屑重量,采用Kruskal-Wallis和Mann-Whitney U检验,显著性水平P<.05。

主要发现

  • 手用器械碎屑挤出显著多于K3XF各组(P<.05)。
  • K3XF不同运动方式中,往复运动碎屑挤出均值最高、连续旋转最低,但差异无统计学意义(P>.05)。
  • 各组间冲洗液挤出量无显著差异(P>.05)。

临床怎么用

  • 临床根管预备时可优先选择K3XF等机用镍钛系统以减少根尖碎屑挤出。
  • 应认识到任何器械运动方式均可能造成根尖碎屑和冲洗液挤出。

局限性

  • 为体外研究,使用离体下颌前磨牙,结果外推至临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This in vitro study was designed to evaluate the amount of apically extruded irrigant and debris during root canal preparation using K3XF instruments (SybronEndo, Orange, CA) with different kinematics and using hand files with a step-back technique. METHODS: A total of 80 extracted mandibular premolars were selected and randomly assigned to 4 groups (n = 20). The root canals were instrumented with K-type stainless steel instruments using a step-back technique and with the K3XF system using the following kinematics: reciprocating motion, adaptive motion, and continuous rotation. Bidistilled water was used as an irrigant. Preweighed Eppendorf tubes were used to collect apically extruded debris during instrumentation. Extruded irrigant was collected from the drainage cannula using a plastic insulin syringe, and the volumes were recorded. After complete evaporation of the liquid inside the tube, the weight of extruded debris was determined for each specimen. Data were analyzed statistically using the Kruskal-Wallis and Mann-Whitney U tests at a significance level of P < .05. RESULTS: Hand file instrumentation was associated with a significantly greater extrusion of debris compared with the K3XF groups (P < .05). Among the different kinematics, the highest mean debris extrusion value was obtained with reciprocating motion and the least with continuous rotation, but this difference was not significant (P > .05). No significant differences were observed between groups in terms of irrigant extrusion (P > .05). CONCLUSIONS: Hand instrumentation extruded more debris than K3XF instruments that were used with different kinematics. All instrumentation kinematics were associated with apical debris and irrigant extrusion.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Toyoğlu M, Altunbaş D. Influence of Different Kinematics on Apical Extrusion of Irrigant and Debris during Canal Preparation Using K3XF Instruments. J Endod. 2017. PMID: 28735794. doi:10.1016/j.joen.2017.05.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。