上颌磨牙开髓洞型设计对根管检出、器械效能与抗折性的影响
研究将30颗离体上颌第一磨牙随机分为缩窄开髓洞型(CEC)与传统开髓洞型(TEC)组,比较根管检出、器械预备效能及抗折性。结果显示TEC组在未使用超声辅助时根管检出更多,但两组非预备根管面积、硬组织碎屑及抗折性无显著差异。CEC未显示优势。
要点
- CEC在未用超声辅助时根管检出少于TEC。
- 两组非预备根管面积及硬组织碎屑无显著差异。
- CEC未提高上颌磨牙抗折性。
核心结论
- 缩窄开髓洞型(CEC)在上颌磨牙中未显示优势,未增加抗折性,且在不使用超声辅助时根管检出较少。
研究设计与样本
- 研究纳入30颗离体上颌第一磨牙,随机分为CEC组和TEC组,每组15颗,采用微计算机断层扫描评估。
主要发现
- 在未放大和手术显微镜下,TEC组根管检出数显著多于CEC组(P < .05);加用超声辅助后两组无差异(P > .05)。
- 非预备根管面积百分比CEC组为25.8% ± 9.7%,TEC组为27.4% ± 8.5%,组间无显著差异。
- 预备后硬组织碎屑百分比CEC组为0.9% ± 0.6%,TEC组为1.3% ± 1.4%,组间无显著差异。
- CEC组在腭根距根尖7 mm处根管偏移显著大于TEC组(P < .05)。
- 抗折性CEC组为996.30 ± 490.78 N,TEC组为937.55 ± 347.25 N,组间无显著差异(P > .05)。
临床怎么用
- 上颌磨牙采用缩窄开髓洞型时,建议配合手术显微镜和超声辅助以改善根管检出。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to assess the influence of contracted endodontic cavities (CECs) on root canal detection, instrumentation efficacy, and fracture resistance assessed in maxillary molars. Traditional endodontic cavities (TECs) were used as a reference for comparison. METHODS: Thirty extracted intact maxillary first molars were scanned with micro-computed tomographic imaging at a resolution of 21 μm, assigned to the CEC or TEC group (n = 15/group), and accessed accordingly. Root canal detection was performed in 3 stages: (1) no magnification, (2) under an operating microscope (OM), and (3) under an OM and ultrasonic troughing. After root canal preparation with Reciproc instruments (VDW GmbH, Munich, Germany), the specimens were scanned again. The noninstrumented canal area, hard tissue debris accumulation, canal transportation, and centering ratio were analyzed. After root canal filling and cavity restoration, the sample was submitted to the fracture resistance test. Data were analyzed using the Fisher exact, Shapiro-Wilk, and t tests (α = 0.05). RESULTS: It was possible to locate more root canals in the TEC group in stages 1 and 2 (P < .05), whereas no differences were observed after stage 3 (P > .05). The percentage of noninstrumented canal areas did not differ significantly between the CEC (25.8% ± 9.7%) and TEC (27.4% ± 8.5%) groups. No significant differences were observed in the percentage of accumulated hard tissue debris after preparation (CEC: 0.9% ± 0.6% and TEC: 1.3% ± 1.4%). Canal transportation was significantly higher for the CEC group in the palatal canal at 7 mm from the apical end (P < .05). Canal preparation was more centralized in the palatal canal of the TEC group at 5 and 7 mm from the apical end (P < .05) and in the distobuccal canal of the CEC group at 5 mm from the apical end (P < .05). There was no difference regarding fracture resistance among the CEC (996.30 ± 490.78 N) and TEC (937.55 ± 347.25 N) groups (P > .05). CONCLUSIONS: The current results did not show benefits associated with CECs. This access modality in maxillary molars resulted in less root canal detection when no ultrasonic troughing associated to an OM was used and did not increase fracture resistance.
引用
- Rover G, Belladonna FG, Bortoluzzi EA, et al. Influence of Access Cavity Design on Root Canal Detection, Instrumentation Efficacy, and Fracture Resistance Assessed in Maxillary Molars. J Endod. 2017. PMID: 28739013. doi:10.1016/j.joen.2017.05.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。