文献速递牙体牙髓病

XP Shaper自适应核心旋转器械的微CT成形能力分析

XP Shaper, A Novel Adaptive Core Rotary Instrument: Micro-computed Tomographic Analysis of Its Shaping Abilities.
PubMed 文献 · J Endod · 2017-07-20

XP Shaper组未触及壁百分比显著更低(38.6%±8.1% vs 58.8%±8.5%),牙本质去除量、根管体积和表面积增加更显著,且预备时间快约1分钟。结论认为XP Shaper能适应根管解剖并接触更多 oval 根管壁,但最终锥度随牙齿解剖变化。

要点

  • XP Shaper较Vortex Blue显著减少未触及根管壁(38.6% vs 58.8%)。
  • XP Shaper去除更多牙本质并增加根管体积和表面积。
  • XP Shaper机械预备时间快约1分钟,碎屑残留有减少趋势但未达显著。

核心结论

  • XP Shaper能超出核心尺寸适应根管解剖,在椭圆形根管中比Vortex Blue预备并接触更多根管壁。
  • 最终预备锥度将根据所治疗牙齿的解剖结构而变化。

研究设计与样本

  • 术前以25-μm分辨率扫描,术后分别用Vortex Blue冠向下至30.04或XP Shaper预备后再扫描。
  • 比较未触及壁百分比、根管体积和表面积变化、牙本质去除量、碎屑残留、预备锥度和器械时间。

主要发现

  • XP Shaper组未触及壁百分比为38.6%±8.1%,显著低于Vortex Blue组的58.8%±8.5%。
  • XP Shaper显著增加根管体积(F=77.948,P<.001)、表面积(F=5.543,P=.030)和牙本质去除量(F=10.044,P=.001)。
  • XP Shaper组根管各水平碎屑均较少,结果接近显著(P=.059)。
  • XP Shaper完成机械预备时间快约1分钟(t=6.216,P<.001)。

关键数值与推荐

  • 未触及壁百分比:XP Shaper组38.6%±8.1%,Vortex Blue组58.8%±8.5%。
  • 根管体积变化:XP Shaper显著增加(F=77.948,P<.001)。
  • 表面积变化:XP Shaper显著增加(F=5.543,P=.030)。
  • 牙本质去除量:XP Shaper显著更多(F=10.044,P=.001)。
  • 预备时间:XP Shaper快约1分钟(t=6.216,P<.001)。

临床怎么用

  • 在椭圆形根管中可优先考虑XP Shaper以增加根管壁接触和清洁。
  • 使用XP Shaper时需注意其最终预备锥度因牙齿解剖而异。
  • XP Shaper可缩短机械预备时间,但碎屑减少趋势需进一步验证。

局限性

  • 研究仅使用离体下颌中切牙单椭圆形根管样本,结果可能不适用于其他牙位或根管形态。
  • 碎屑残留差异仅接近显著(P=.059),需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to investigate the shaping abilities of the XP Shaper (FKG, La Chaux-de-Fonds, Switzerland) and compare the findings with Vortex Blue (Dentsply Tulsa Dental Specialties, Tulsa, OK) using micro-computed tomographic imaging. METHODS: Twenty matched, extracted, mandibular, central incisors with a single, oval canal were scanned preoperatively at 25-μm resolution and postoperatively after instrumentation with either Vortex Blue in a crown-down manner up to size 30.04 or XP Shaper. The percent of untouched walls, changes in canal volume and surface area, the amount of dentin removed, debris remaining in the canal, and the preparation taper were determined. The total time required for instrumentation using each technique was calculated in seconds. Statistical analysis was used to compare between both groups using repeated measures multivariate analysis of variance with Bonferroni correction for post hoc comparison and independent sample t tests. RESULTS: The XP Shaper significantly increased the canal volume (F = 77.948, P < .001), surface area (F = 5.543, P = .030), and amount of dentin removed (F = 10.044, P = .001) and had significantly less untouched walls (38.6% ± 8.1%) compared with VB (58.8% ± 8.5%). There was less debris at all levels of the canal in the XP Shaper group. Results were almost significant (P = .059). The XP Shaper was also significantly faster in completing the mechanical preparation of the root canal space by almost 1 minute (t = 6.216, P < .001). CONCLUSIONS: The XP Shaper can expand beyond its core size to adapt to the anatomy of the root canal space. The XP Shaper can prepare and touch more canal walls in oval-shaped canals compared with Vortex Blue. However, the final preparation taper will vary according to the anatomy of the treated tooth.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Azim AA, Piasecki L, da Silva Neto UX, et al. XP Shaper, A Novel Adaptive Core Rotary Instrument: Micro-computed Tomographic Analysis of Its Shaping Abilities. J Endod. 2017. PMID: 28735789. doi:10.1016/j.joen.2017.04.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。