文献速递牙体牙髓病

Micro-CT评估四种根管预备系统在椭圆形根管中的成形能力

Micro-CT assessment of the shaping ability of four root canal instrumentation systems in oval-shaped canals.
PubMed 文献 · Int Endod J · 2017-07-31

结果显示各组硬组织碎屑百分比无显著差异,BioRace未触及根管壁比例显著高于Reciproc和SAF,Reciproc去除牙本质显著多于BioRace和SAF,TRUShape各项指标居中。所有系统均未能实现椭圆形根管的最优成形。

要点

  • 四种系统残留硬组织碎屑百分比无显著差异(P=0.126)。
  • BioRace未触及根管壁比例(32.38%)显著高于Reciproc(18.95%)和SAF(16.08%)。
  • Reciproc去除牙本质(4.18%)显著多于BioRace(2.21%)和SAF(2.56%)。

核心结论

  • 四种预备技术产生的硬组织碎屑量相同。
  • BioRace与更多未触及根管壁相关,Reciproc去除牙本质最多。
  • SAF触及更多根管壁但去除牙本质较少,TRUShape各项指标居中。
  • 所有测试系统均无法在椭圆形根管中提供最优成形能力。

研究设计与样本

  • 采用Micro-CT分析比较四种根管预备系统的成形能力。
  • 预备前后扫描并配准数据集,评估硬组织碎屑、未触及根管壁和去除牙本质的百分比。
  • 使用Kruskal-Wallis和Mann-Whitney U检验(Bonferroni校正,α=5%)比较组间变量。

主要发现

  • 预备技术未影响硬组织碎屑百分比(P=0.126)。
  • BioRace未触及根管壁面积百分比(32.38%)显著高于Reciproc(18.95%)和SAF(16.08%)(P<0.05)。
  • Reciproc去除牙本质(4.18%)显著多于BioRace(2.21%)和SAF(2.56%)(P<0.05)。
  • TRUShape未触及根管壁(19.20%)和去除牙本质(3.77%)与其余三组无显著差异。

临床怎么用

  • 在椭圆形根管预备中,需权衡根管壁触及率与牙本质去除量。
  • 若优先减少未触及根管壁,可考虑SAF或Reciproc而非BioRace。
  • 若优先保留牙本质,可考虑BioRace或SAF而非Reciproc。
  • TRUShape在未触及壁和牙本质去除间呈中间表现。
  • 现有系统均不能实现椭圆形根管的最优成形,需结合临床选择。

局限性

  • 仅评估三个指标,未涉及其他成形参数。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the shaping ability of four root canal instrumentation systems in oval-shaped canals using micro-computed tomographic analysis. METHODOLOGY: Forty anatomically matched mandibular incisors were scanned and assigned to four groups (n = 10), according to the canal preparation protocol: BioRace, Reciproc, Self-Adjusting File (SAF) and TRUShape systems. After canal instrumentation, the specimens were rescanned, and the registered pre- and postoperative datasets were examined to evaluate the percentages of accumulated hard-tissue debris, untouched canal walls and dentine removed. Kruskal-Wallis and Mann-Whitney U-tests with Bonferroni correction were used to compare the variables in the groups (α = 5%). RESULTS: The preparation techniques did not affect the percentage of accumulated hard-tissue debris (P = 0.126). The percentage of untouched canal areas was significantly higher for BioRace (32.38%)compared to Reciproc (18.95%) and SAF (16.08%) systems (P < 0.05). Reciproc removed significantly more dentine (4.18%) than BioRace (2.21%) and SAF (2.56%) (P < 0.05). The TRUShape system had intermediate results for both untouched canal walls (19.20%) and dentine removed (3.77%), with no significant difference compared to BioRace, Reciproc and SAF systems. CONCLUSIONS: The preparation techniques resulted in the same level of accumulated hard-tissue debris. Compared to the other tested systems, BioRace was associated with more untouched canal walls and Reciproc produced the greatest amount of removed dentine. Although it touched more of the root canal walls, the SAF system removed less dentine, whereas TRUShape had intermediate results for these same parameters. None of the systems tested were able to provide optimal shaping ability in oval-shaped canals.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Zuolo ML, Zaia AA, Belladonna FG, et al. Micro-CT assessment of the shaping ability of four root canal instrumentation systems in oval-shaped canals. Int Endod J. 2017. PMID: 28667674. doi:10.1111/iej.12810

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。