两种集成根尖定位仪根管马达的准确性比较

Accuracy of 2 Endodontic Rotary Motors with Integrated Apex Locator.
PubMed 文献 · J Endod · 2017-07-20

本研究体外评估MM Control与Root ZX II两种根管马达的电子根尖定位仪(EAL)和自动根尖反转(AAR)功能的准确性。对36颗单根牙进行颈部分预扩后,用藻酸盐模型测量EAL在「APEX」和「0.5」标记的读数,并随机分两组用AAR功能(0.5标记)预备根管。结果显示两设备EAL测量均值和AAR长度无差异(ANOVA,P > .05),但MM Control的EAL功能出现更多超过实际长度1.01 mm以上的测量(卡方,P < .01)。结论:两者AAR功能均提供可接受的根尖预备止点,但仅用MM Control的EAL功能会导致显著更多过度延伸读数。

要点

  • MM Control与Root ZX II的AAR功能均能在体外提供可接受的根尖预备止点。
  • MM Control的EAL功能出现超过实际长度1.01 mm以上的测量比例显著更高。
  • 两设备EAL测量均值及AAR长度无统计学差异。

核心结论

  • MM Control和Root ZX II的AAR功能在体外均能提供足够的根尖预备止点。
  • 仅使用MM Control的EAL功能会导致显著更多过度延伸的读数。

研究设计与样本

  • 体外研究,使用36颗单根牙,颈部分预扩后获得实际长度(AL)。
  • 用藻酸盐模型获取两种设备在「APEX」和「0.5」标记的EAL测量值。
  • 牙齿随机分为2组(每组18颗),分别用各马达的AAR功能(0.5标记)进行根管预备。
  • 比较AAR提供的长度与预备后视觉长度(AL2),并比较设备间电子测量绝对值的均值和分布百分比。

主要发现

  • 两种设备在EAL测量均值或AAR长度上无差异(方差分析,P > .05)。
  • MM Control的EAL功能出现超过AL 1.01 mm以上的测量百分比更高(卡方检验,P < .01)。
  • AAR功能在Root ZX中83.3%的病例提供可接受的根尖止点,在MM Control中为77.8%。

关键数值与推荐

  • AAR功能可接受根尖止点:Root ZX II为83.3%的病例,MM Control为77.8%的病例。
  • EAL测量超过AL 1.01 mm以上的百分比:MM Control显著高于Root ZX II(卡方,P < .01)。

临床怎么用

  • 临床使用MM Control时,不宜仅依赖其EAL功能,应结合其他方法确认工作长度。
  • 两种马达的AAR功能均可用于辅助确定根尖预备止点。

局限性

  • 本研究为体外研究,结果需临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study was to evaluate in vitro the efficacy of both the electronic apex locator (EAL) and auto apical reverse (AAR) functions of the endodontic motor MM Control (Micro-Mega, Besançon Cedex, France) compared with Root ZX II (J Morita, Tokyo, Japan). METHODS: After cervical preflaring, the actual lengths (ALs) of 36 single-rooted teeth were obtained up to the apical foramen. The EAL measurements at the marks "APEX" and "0.5" of both devices were obtained using an alginate model. The teeth were divided randomly into 2 groups (n = 18), and root canal preparation was performed with rotary instruments using the AAR function (0.5 mark) of each motor. The length provided by the AAR was compared with the visual length after preparation (AL2). The differences between the electronic lengths and the respective visual measurements were assigned as negative for lower or positive when higher. The means of the absolute values and the percentages of distribution of the electronic measurements between devices were compared. RESULTS: There was no difference between the devices in terms of the means of the EAL measurements or AAR length (analysis of variance, P > .05). However, the EAL function of MM Control presented a greater percentage of measurements >1.01 mm longer than AL (chi-square, P < .01). The AAR function provided an acceptable apical limit in 83.3% of the cases for Root ZX and 77.8% of the cases for MM Control. CONCLUSIONS: The AAR function of both MM Control and Root ZX II provided an adequate apical limit of preparation in vitro. However, the use of only the EAL function of MM Control resulted in significantly more cases of overextended readings.