文献速递口腔修复与种植

微螺纹对反锥形窄直径种植体冠部骨愈合的影响:比格犬研究

Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs.
PubMed 文献 · Clin Oral Implants Res · 2017-05-22

本研究在6只比格犬无牙下颌以裂口设计植入52枚种植体,比较有无冠部微螺纹的反锥形窄直径种植体(RTN与RTNM)的冠部骨愈合。结果显示RTNM组在4周和8周时冠部骨-种植体接触体积及体积比显著高于RTN组,4周时冠部骨-种植体接触长度也显著更高,但8周时两组骨-种植体接触长度与比率无显著差异,种植体稳定性和移除扭矩在各时间点均无显著差异。结论提示微螺纹可能在早期愈合阶段通过增加表面积促进更多冠部骨-种植体接触,但8周时对冠部骨愈合无显著影响。

要点

  • 微螺纹在早期(4周)可增加冠部骨-种植体接触体积与长度。
  • 8周时微螺纹对冠部骨-种植体接触长度与比率无显著影响。
  • 两组种植体稳定性和移除扭矩在各时间点均无显著差异。

核心结论

  • 微螺纹可能在早期愈合阶段通过增加表面积促进更多冠部骨-种植体接触,但8周时对冠部骨愈合无显著影响。

研究设计与样本

  • 研究共纳入52枚种植体,按有无冠部微螺纹分为反锥形窄直径种植体组(RTN)和反锥形窄直径带微螺纹种植体组(RTNM)。
  • 种植体以裂口设计植入6只比格犬的无牙下颌,3只在4周时处死,3只在8周时处死。
  • 检测包括共振频率分析、微计算机断层扫描(micro-CT)骨测量、移除扭矩测试和组织形态学分析。

主要发现

  • 种植体稳定商值在基线、4周或8周时两组间均无显著差异。
  • micro-CT显示RTNM组冠部骨-种植体接触体积(BICV)和骨-种植体接触体积比(BICVR)在4周和8周时均显著高于RTN组。
  • 组织形态学分析显示4周时RTNM组冠部骨-种植体接触长度(BICL)显著高于RTN组,但骨-种植体接触比率(BICR)两组间无显著差异。
  • 8周时两组间BICL和BICR均无显著差异。
  • 移除扭矩测试显示4周和8周时两组间均无显著差异。

关键数值与推荐

  • RTNM组冠部BICV和BICVR在4周和8周时均显著高于RTN组(具体数值原文未报告)。
  • 4周时RTNM组冠部BICL显著高于RTN组(具体数值原文未报告)。
  • 4周时两组间BICR无显著差异(具体数值原文未报告)。
  • 8周时两组间BICL和BICR均无显著差异(具体数值原文未报告)。
  • 种植体稳定商值和移除扭矩在各时间点两组间均无显著差异(具体数值原文未报告)。

临床怎么用

  • 对于反锥形窄直径种植体,冠部微螺纹设计可能有助于早期冠部骨-种植体接触。
  • 微螺纹设计对8周时的冠部骨愈合无显著额外获益。
  • 临床决策需结合长期疗效综合评估,不能仅依据早期骨接触指标。

局限性

  • 研究为动物实验(比格犬),结果外推至人类需谨慎。
  • 样本量较小(6只犬,52枚种植体),观察期较短(仅4周和8周)。
  • 原文未报告具体数值和统计细节,无法进行定量比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective of this study was to investigate the effect of microthreads on the coronal bone healing of narrow-diameter implants with reverse-tapered design. MATERIAL AND METHODS: A total of 52 implants were classified into two groups according to presence or absence of coronal microthreads, the reverse-tapered narrow-diameter implant (RTN) group, and the reverse-tapered narrow-diameter implant with microthreads (RTNM) group. The implants were installed in split-mouth design in the edentulous mandible of six dogs. Three animals were sacrificed at 4 weeks and three at 8 weeks. Resonance frequency analysis, bone measurement using microcomputed tomography (micro-CT), removal torque test, and histometric analysis were performed. RESULTS: No significant differences in implant stability quotient value were observed between the groups at baseline, 4 weeks, or 8 weeks. Bone measurement using micro-CT showed that bone-implant contact volume (BICV) and bone-implant contact volume ratio (BICVR) in the coronal part of RTNM were statistically higher than those in RTN at 4 and 8 weeks. Histometric analysis showed statistically higher bone-implant contact length (BICL) in the coronal part of RTNM than in RTN at 4 weeks; however, bone-implant contact ratio (BICR) was not significantly different between the groups. At 8 weeks, the BICL and BICR did not differ significantly between the groups. Removal torque test showed no significant differences between the groups at 4 and 8 weeks. CONCLUSIONS: The microthreads might facilitate more coronal bone-implant contact due to increased surface areas at an early healing phase; however, they did not significantly affect coronal bone healing at 8 weeks.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Chang YY, Kim SH, Park KO, et al. Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs. Clin Oral Implants Res. 2017. PMID: 28543806. doi:10.1111/clr.13022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。