本研究以显微CT为金标准,由2名口腔放射科医师对114颗离体人类前磨牙的根尖片与锥形束CT图像进行评估,按Vertucci分类记录根管构型。锥形束CT的诊断准确率为0.89,根尖片为0.55;锥形束CT与金标准无差异,根尖片与两者均有差异(P < .0001)。
要点
- 锥形束CT诊断前磨牙根管构型的准确率为0.89,根尖片为0.55。
- 锥形束CT与显微CT金标准无差异,根尖片与锥形束CT及金标准均有差异(P < .0001)。
- 复杂根管构型在两种影像方法下均较难识别,根尖片尤为明显。
核心结论
- 根尖片在检测前磨牙根管构型方面表现较差,而锥形束CT与金标准无差异。
- 复杂根管构型在两种影像方法下均较难识别,尤其是根尖片。
研究设计与样本
- 对114颗离体人类前磨牙的根尖片与锥形束CT图像进行评估,由2名口腔放射科医师判读。
- 按Vertucci分类记录根管构型,以显微CT成像作为金标准。
- 计算准确率、灵敏度、特异度和预测值,采用Friedman检验比较根尖片和锥形束CT与金标准。
主要发现
- 锥形束CT在所有诊断指标上均显示高于根尖片的数值。
- 准确率:根尖片为0.55,锥形束CT为0.89。
- 锥形束CT与金标准之间无差异,根尖片与锥形束CT及显微CT之间均有差异(P < .0001)。
- 锥形束CT对III型、VII型和「其他」型根管构型的识别准确率分别为50%、0%和43%。
- 根尖片除I型外,所有根管构型均显示不清。
关键数值与推荐
- 根管构型按Vertucci分类记录。
- 以显微CT成像作为确定根管构型的金标准。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. METHODS: PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. RESULTS: CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. CONCLUSIONS: PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR.
引用
- Sousa TO, Haiter-Neto F, Nascimento EHL, et al. Diagnostic Accuracy of Periapical Radiography and Cone-beam Computed Tomography in Identifying Root Canal Configuration of Human Premolars. J Endod. 2017. PMID: 28527842. doi:10.1016/j.joen.2017.02.021