器械操作技术与预备锥度对细菌根尖推出物的影响
这项体外研究将98颗离体下颌切牙根管感染粪肠球菌后,分别用K3旋转镍钛锉以冠向下法或全根长线性法配合0.02、0.04、0.06三种锥度进行预备,收集根尖推出细菌并计数菌落形成单位。结果显示0.02锥度配合冠向下法推出细菌最少,而0.04和0.06锥度下操作技术对推出细菌量无明显影响。
要点
- 0.02锥度冠向下法预备时根尖推出细菌量最少。
- 全根长线性法下预备锥度对菌落形成单位数无显著影响。
- 0.04和0.06锥度时冠向下法与全根长线性法推出细菌量无显著差异。
核心结论
- 采用0.02锥度以冠向下法预备时根尖推出细菌量最少。
- 使用0.04和0.06锥度器械清理成形根管时,操作技术似乎不影响细菌推出量。
研究设计与样本
- 体外研究,使用98颗离体人下颌切牙,根管感染粪肠球菌悬液后37°C孵育24小时。
- 根管分别用K3旋转锉以冠向下法或全根长线性法配合0.02、0.04、0.06三种锥度进行预备。
主要发现
- 全根长线性法下预备锥度对菌落形成单位数无影响(P > .05)。
- 预备锥度为0.02时,全根长线性法与冠向下法之间的菌落形成单位数有统计学显著差异(P < .05)。
- 0.04和0.06锥度在任何操作技术之间均无统计学显著差异(P > .05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this in vitro study was to evaluate the effects of different root canal instrumentation techniques and preparation tapers on the amount of apically extruded bacteria. METHODS: The root canals of 98 extracted human mandibular incisors were contaminated with Enterococcus faecalis suspension. After incubation at 37°C for 24 hours, the root canals were instrumented with K3 rotary files in a crown-down (CD) or full-length linear instrumentation technique (FL) by using 3 different root canal tapers (0.02, 0.04, and 0.06). During instrumentation, apically extruded bacteria were collected into vials containing saline solution. The microbiological samples were taken from the vials and incubated in brain-heart agar medium for 24 hours, and the numbers of colony-forming units (CFUs) were determined. The obtained results were analyzed with t test and one-way analysis of variance for the comparisons between the instrumentation techniques (CD and FL) and the preparation tapers (0.02, 0.04, and 0.06), respectively. Tukey honestly significant difference test was used for pairwise comparisons. RESULTS: The preparation taper had no effect on the number of CFUs when a FL instrumentation technique was used (P > .05). There was a statistically significant difference in the CFUs between FL and CD techniques when the preparation taper was 0.02 (P < .05). There was no statistically significant difference between the 0.04 and 0.06 preparation tapers in any of the instrumentation techniques (P > .05). CONCLUSIONS: Using a 0.02 taper in a CD manner results in the least amount of bacterial extrusion. The instrumentation technique did not seem to affect the amount of bacterial extrusion when 0.04 and 0.06 taper instruments were used for cleaning and shaping the root canal space.
引用
- Aksel H, Küçükkaya Eren S, Çakar A, et al. Effect of Instrumentation Techniques and Preparation Taper on Apical Extrusion of Bacteria. J Endod. 2017. PMID: 28416303. doi:10.1016/j.joen.2017.01.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。