逆时针或顺时针往复运动预备椭圆形根管:micro-CT分析
本研究用micro-CT评估下颌切牙椭圆形根管分别采用逆时针往复运动单支锉或顺时针往复运动单支/双支锉预备的效果。结果显示不同运动方式下根管体积增加和未预备面积百分比相似,双支锉在根管中三分之一残留碎屑显著少于单支锉。
要点
- 不同往复运动方式预备后根管体积增加和未预备面积百分比相似。
- 双支锉M20/40.06在根管中三分之一碎屑百分比显著低于R40和M40.06。
- 结论基于57颗下颌切牙的micro-CT分析。
核心结论
- R40常规逆向往复运动和Mtwo顺时针往复运动 resulted in similar root canal preparations.
- 使用两支不同直径的器械时,根管中三分之一残留碎屑更少。
研究设计与样本
- 选取57颗下颌人切牙的椭圆形根管(2 ≤ 直径比 ≤ 4),随机分为3组(n=19)进行根管预备。
- 分别使用R40逆时针往复运动、M40.06顺时针往复运动或M20/40.06顺时针往复运动预备。
- 预备前后用SkyScan 1176 micro-CT扫描,分析根管整体及每个三分之一的体积、碎屑百分比和未预备面积百分比。
主要发现
- R40和Mtwo系统在不同运动方式下根管体积增加相似。
- 两种系统的未预备面积百分比相似(P > 0.05)。
- M20/40.06组根管中三分之一碎屑百分比为0.56%,显著低于R40组的1.31%和M40.06组的1.54%(P < 0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate oval root canal preparation using one or two instruments in counterclockwise or clockwise reciprocating motion. METHODOLOGY: The radiographic diameter of mandibular human incisors was evaluated, and oval canals were selected (2 ≤ Diameter Ratio ≤ 4). Fifty-seven teeth were assigned to root canal preparation (n = 19): Reciproc 40 (R40) in a counterclockwise reciprocating motion; Mtwo size 40, .06 taper (M 40.06) in a clockwise reciprocating motion or Mtwo size 20, .06 taper and size 40, .06 taper (M 20/40.06) in a clockwise reciprocating motion. Mtwo instruments were coupled to an ENDO DUAL motor, turning 150° clockwise and 30° counterclockwise. Scanning was performed before and after root canal preparation using a SkyScan 1176 micro-computed tomography. Volume, percentage of debris and percentage of uninstrumented surface were analysed in the entire root canal and in each third of the canal. Data were compared using anova and Tukey's tests or Kruskal-Wallis and Dunn tests. RESULTS: The Reciproc and Mtwo systems using different kinematics were associated with a similar increase in root canal volume. Additionally, both system had similar percentage of uninstrumented surface (P > 0.05). Mtwo size 20, .06 taper and size 40, .06 taper was associated with significantly lower debris (P < 0.05) in the middle third (0.56%) when compared to R40 (1.31%) and M size 40, .06 taper (1.54%). CONCLUSIONS: The conventional reciprocation motion for R40 and the clockwise reciprocation motion for Mtwo resulted in similar root canal preparations. Less remaining debris was present in the middle third when two instruments with different diameters were used.
引用
- Espir CG, Nascimento-Mendes CA, Guerreiro-Tanomaru JM, et al. Counterclockwise or clockwise reciprocating motion for oval root canal preparation: a micro-CT analysis. Int Endod J. 2017. PMID: 28375575. doi:10.1111/iej.12776
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。