机械与化学性菌斑控制同步管理牙龈炎与龋病的系统综述
本系统综述纳入15项随机对照试验、10项对照临床试验和2项前瞻性病例系列,评估机械和/或化学性菌斑控制同步管理牙龈炎与龋病的证据。低至中等证据支持专业与自我机械菌斑控制联合可显著降低标准化菌斑指数(WMD=1.294,95%CI 0.445–2.144,P=0.003)和牙龈炎评分(WMD=1.728,95%CI 0.631–2.825,P=0.002);机械菌斑控制加氟对龋管理有意义(WMD=1.159,95%CI 0.145–2.172,P=0.025),氯己定漱口水对牙龈炎有益但对龋作用不确定。
要点
- 专业与自我机械菌斑控制联合显著降低菌斑指数和牙龈炎评分。
- 机械菌斑控制加氟对龋管理有显著意义。
- 氯己定漱口水对牙龈炎有益,对龋作用不确定。
核心结论
- 机械菌斑控制程序可有效减少菌斑和牙龈炎。
- 机械菌斑控制加氟对龋管理有显著意义。
- 氯己定漱口水对牙龈炎有正面作用,对龋作用不确定。
研究设计与样本
- 设计方案识别至少随访6个月的随机对照试验、对照临床试验、队列研究和前瞻性病例系列。
- 筛选1373篇标题后纳入15项随机对照试验、10项对照临床试验和2项前瞻性病例系列。
- 从全文提取包括质量和偏倚风险在内的相关信息,并在可能时进行Meta分析。
主要发现
- 低至中等证据支持专业与自我机械菌斑控制联合显著降低标准化菌斑指数(n=4;WMD=1.294;95%CI 0.445–2.144;P=0.003)。
- 低至中等证据支持专业与自我机械菌斑控制联合显著降低牙龈炎评分(n=4;WMD=1.728;95%CI 0.631–2.825;P=0.002)。
- 机械菌斑控制加氟对龋管理有意义(n=5;WMD=1.159;95%CI 0.145–2.172;P=0.025)。
- 氯己定漱口水对牙龈炎有益,对龋作用不确定。
关键数值与推荐
- 标准化菌斑指数:专业与自我机械菌斑控制联合组WMD=1.294(95%CI 0.445–2.144;P=0.003;n=4)。
- 牙龈炎评分:专业与自我机械菌斑控制联合组WMD=1.728(95%CI 0.631–2.825;P=0.002;n=4)。
- 龋管理:机械菌斑控制加氟组WMD=1.159(95%CI 0.145–2.172;P=0.025;n=5)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To report the evidence on the effect of mechanical and/or chemical plaque control in the simultaneous management of gingivitis and caries. MATERIAL AND METHODS: A protocol was designed to identify randomized (RCTs) and controlled (CCTs) clinical trials, cohort studies and prospective case series (PCS), with at least 6 months of follow-up, reporting on plaque, gingivitis and caries. Relevant information was extracted from full papers, including quality and risk of bias. Meta-analyses were performed whenever possible. RESULTS: After the screening of 1,373 titles, 15 RCTs, 10 CCTs and 2 PCS were included. Low to moderate evidence support that combined professional and self-performed mechanical plaque control significantly reduces standardized plaque index [n = 4; weighted mean difference (WMD) = 1.294; 95% CI (0.445; 2.144); p = 0.003] and gingivitis scores [n = 4; WMD = 1.728; 95% CI (0.631; 2.825); p = 0.002]. The addition of fluoride to mechanical plaque control is relevant for caries management [n = 5; WMD = 1.159; 95% CI (0.145; 2.172); p = 0.025] while chlorhexidine rinses are relevant for gingivitis. CONCLUSION: Mechanical plaque control procedures are effective in reducing plaque and gingivitis. The addition of fluoride to mechanical plaque control is significant for caries management. Chlorhexidine rinse has a positive effect on gingivitis and inconclusive role in caries.
引用
- Figuero E, Nóbrega DF, García-Gargallo M, et al. Mechanical and chemical plaque control in the simultaneous management of gingivitis and caries: a systematic review. J Clin Periodontol. 2017. PMID: 28266113. doi:10.1111/jcpe.12674
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。