一种利用微型计算机断层扫描评估牙髓材料流动性的新模型
本研究提出一种利用微型计算机断层扫描(μCT)评估牙髓材料流动性的新技术,并与国际标准化组织(ISO)6876/2002方法对比。结果显示,氧化锌丁香酚(ZOE)在ISO方法下流动性最高(P < .05),而BIO的侧腔填充能力优于ZOE。该μCT模型结果可靠且可重复,有望改进流动性分析。
要点
- ZOE在ISO方法下流动性最高(P < .05)。
- μCT显示MTA-Angelus和ZOE在沟槽中线性流动速率较高。
- BIO的侧腔填充能力优于ZOE。
核心结论
- 尽管ZOE在ISO方法下流动性更好,但BIO表现出最佳的填充能力。
- 所提出的μCT评估流动性模型结果可靠且可重复,有望改进流动性分析。
研究设计与样本
- 体外研究,使用带有中央腔和4条水平与垂直沟槽的玻璃板,评估MTA-Angelus、氧化锌丁香酚(ZOE)和Biodentine(BIO)的流动性。
- 采用ISO 6876/2002方法和新技术(放置0.05 ± 0.005 mL材料,覆盖总质量120 g的玻璃板和金属砝码,进行μCT扫描)进行对比。
- 通过沟槽中材料的线性测量(mm)计算流动性,中央腔填充以mm3计算,侧腔填充(LCF)测量距中央腔2 mm内的平均值。
- 数据分析使用方差分析和Tukey检验,显著性水平为5%。
主要发现
- ZOE在ISO方法下流动性最高(P < .05)。
- μCT分析显示MTA-Angelus和ZOE在沟槽中线性流动速率较高。
- 各材料的中央腔填充相似。
- BIO的侧腔填充(LCF)高于ZOE。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Flow and filling ability are important properties of endodontic materials. The aim of this study was to propose a new technique for evaluating flow using micro-computed tomographic (μCT) imaging. METHODS: A glass plate was manufactured with a central cavity and 4 grooves extending out horizontally and vertically. The flow of MTA-Angelus (Angelus, Londrina, PR, Brazil), zinc oxide eugenol (ZOE), and Biodentine (BIO) (Septodont, Saint Maur des Fossés, France) was evaluated using International Standards Organization (ISO) 6876/2002 and a new technique as follows: 0.05 ± 0.005 mL of each material was placed in the central cavity, and another glass plate and metal weight with a total mass of 120 g were placed over the material. The plate/material set was scanned using μCT imaging. The flow was calculated by linear measurement (mm) of the material in the grooves. Central cavity filling was calculated in mm3 in the central cavity. Lateral cavity filling (LCF) was measured by LCF mean values up to 2 mm from the central cavity. Data were analyzed statistically using analysis of variance and Tukey tests with a 5% significance level. RESULTS: ZOE showed the highest flow rate determined by ISO methodology (P < .05). Analysis performed using μCT imaging showed MTA-Angelus and ZOE had higher linear flow rates in the grooves. Central cavity filling was similar for the materials. However, LCF was higher for BIO versus ZOE. CONCLUSIONS: Although ZOE presented better flow determined by ISO methodology, BIO showed the best filling ability. The model of the technique proposed for evaluating flow using μCT imaging showed proper and reproducible results and could improve flow analysis.
引用
- Tanomaru-Filho M, Torres FFE, Bosso-Martelo R, et al. A Novel Model for Evaluating the Flow of Endodontic Materials Using Micro-computed Tomography. J Endod. 2017. PMID: 28268019. doi:10.1016/j.joen.2016.12.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。