WaveOne与Reciproc器械在后牙根管预备至多3颗牙中的折断发生率:一项前瞻性临床研究

Fracture Incidence of WaveOne and Reciproc Files during Root Canal Preparation of up to 3 Posterior Teeth: A Prospective Clinical Study.
PubMed 文献 · J Endod · 2017-03-23

这项前瞻性临床研究由3名经验丰富的专家在12个月内使用120根往复运动器械(Reciproc R25与WaveOne Primary各60根)治疗358颗后牙(1130个根管),评估器械在至多3次使用中的折断情况。结果显示无器械变形,共3根器械折断(占根管数的0.26%、占牙数的0.84%),全部发生于下颌磨牙。结论为往复运动器械用于至多3例后牙根管治疗时折断发生率低。

要点

  • 3根往复运动器械折断,占1130个根管的0.26%、358颗牙的0.84%。
  • 所有折断均发生于下颌磨牙,包括1根WaveOne Primary(第3次使用)和2根Reciproc R25(第1次及第3次使用各1根)。
  • 无器械出现变形迹象,折断后器械即被丢弃。

核心结论

  • 往复运动器械用于至多3例后牙根管治疗时折断发生率低。

研究设计与样本

  • 前瞻性临床研究,由3名经验丰富的专家在12个月内使用120根往复运动器械(Reciproc R25 60根、WaveOne Primary 60根)治疗358颗后牙(1130个根管)。

主要发现

  • 共3根器械折断,占根管数的0.26%、占牙数的0.84%;无器械出现变形。
  • 所有折断均发生于下颌磨牙:1根WaveOne Primary于第3次使用时折断,2根Reciproc R25分别于第1次和第3次使用时折断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Reciprocating instruments were developed to improve and simplify the preparation of the root canal system by allowing greater centralization of the canal and requiring a shorter learning curve. Despite the risk of instrument separation, using a reciprocating instrument in more than 1 case is a relatively common clinical practice. The aim of this study was to evaluate the fracture resistance of Reciproc (R25; VDW, Munich, Germany) and WaveOne (Primary; Dentsply Maillefer, Ballaigues, Switzerland) instruments according to the number of uses during the preparation of root canals in up to 3 posterior teeth. METHODS: A prospective clinical study was conducted by 3 experienced specialists who performed treatment of 358 posterior teeth (1130 canals) over a period of 12 months using 120 reciprocating instruments, 60 of which were Reciproc R25 and 60 were WaveOne Primary. The motion used during instrumentation followed the recommendations of the respective manufacturers. After each use, the instruments were observed under a dental operating microscope at 8× magnification. In the case of fracture or deformation, the instrument was discarded. RESULTS: None of the instruments showed any signs of deformation, but 3 instruments fractured (0.26% of the number of canals and 0.84% of the number of teeth). All fractures occurred in mandibular molars (1 WaveOne Primary file during the third use and 2 Reciproc R25 files, 1 during the first use and the other during the third use). CONCLUSIONS: There was a low incidence of fracture when reciprocating files were used in up to 3 cases of endodontic treatment in posterior teeth.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Bueno CSP, Oliveira DP, Pelegrine RA, et al. Fracture Incidence of WaveOne and Reciproc Files during Root Canal Preparation of up to 3 Posterior Teeth: A Prospective Clinical Study. J Endod. 2017. PMID: 28343932. doi:10.1016/j.joen.2016.12.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。