两种镍钛器械HyFlex EDM与ProTaper Next根管成形能力的微计算机断层扫描评价
本研究用微计算机断层扫描比较ProTaper Next(PTN)与新型HyFlex EDM(HFEDM)器械的根管成形能力,将40颗牙随机分为两组分别预备。结果显示两组仅在根管中三分之一与冠三分之一交界处颊舌向的根管偏移和中心定位比上差异有统计学意义(P < .005),HFEDM更优,其余指标两组相似,均能安全预备根管并保持原有解剖形态。
要点
- 40颗牙随机分为PTN组与HFEDM组,用微计算机断层扫描评价成形能力
- 仅中三分之一与冠三分之一交界处颊舌向根管偏移和中心定位比两组差异有统计学意义(P < .005),HFEDM更优
- 两组器械均能安全预备根管并保持原有解剖形态,总体效果相似
核心结论
- HFEDM与PTN器械效果相似,均能安全预备根管并保持其原有解剖形态。
- HFEDM在根管中三分之一与冠三分之一交界处颊舌向的根管偏移和中心定位比方面表现更好。
研究设计与样本
- 体外研究:40颗牙随机分为2组,分别用PTN或HFEDM预备。
- 采用微计算机断层扫描成像评价成形能力。
- 在根尖、根中、根冠三分之一的中点及其交界处共5个水平,于近远中向和颊舌向评价根管偏移和中心定位比。
- 测量根尖、根中、根冠三分之一的体积、表面积和横截面形状变化。
- 无效假设为两组间无差异;用D'Agostino-Pearson检验(α = .05)评估数据正态性,用Mann-Whitney检验(α = .05)比较分布。
主要发现
- 仅在中三分之一与冠三分之一交界处的颊舌向根管偏移和中心定位比上记录到统计学显著差异(P < .005),HFEDM器械更优。
- 其余评价指标两组间未见统计学显著差异。
关键数值与推荐
- 统计学显著性水平设定为α = .05;结果中报告统计学显著差异为P < .005。
- 随机分组牙数为40颗,分为2组。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate and compare, by means of micro-computed tomography imaging, the shaping ability of ProTaper Next (PTN) and the novel HyFlex EDM (HFEDM) instruments. METHODS: Forty teeth were randomly divided into 2 groups and prepared with PTN or HFEDM. Root canal transportation and centering ratio were evaluated in mesiodistal and buccolingual directions at 5 levels (at the midpoint of the apical, middle, and coronal thirds and at the boundaries between them). Variations in volume, surface, and cross-sectional shape were measured for the apical, middle, and coronal thirds. The null hypotheses were that no differences existed between the 2 groups. The D'Agostino-Pearson test (α = .05) was conducted to assess the normality of the data sets. The distributions were compared by using the Mann-Whitney test (α = .05). RESULTS: Statistically significant differences (P < .005) were recorded only for buccolingual canal transportation and centering ratio at the section between the middle and coronal thirds, where HFEDM files were superior. CONCLUSIONS: HFEDM and PTN files were similarly effective, and both safely prepared the root canals, respecting their original anatomies. HFEDM files performed better in terms of buccolingual canal transportation and centering ratio at the section between the middle and coronal thirds.
引用
- Venino PM, Citterio CL, Pellegatta A, et al. A Micro-computed Tomography Evaluation of the Shaping Ability of Two Nickel-titanium Instruments, HyFlex EDM and ProTaper Next. J Endod. 2017. PMID: 28215346. doi:10.1016/j.joen.2016.11.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。