不同充填方法下硅酸钙基根管封闭剂的牙本质小管渗透深度
本研究取100颗离体人恒前牙行根管预备,分为CPoint单尖法、牙胶单尖法、牙胶垂直加压法3个实验组及1个对照组,均使用含钙指示剂Fluo-3的硅酸钙基封闭剂;共聚焦激光扫描显微镜测量显示,3组封闭剂最大渗透深度与各位点平均深度均无统计学显著差异。
要点
- CPoint单尖法、牙胶单尖法、牙胶垂直加压法的封闭剂渗透深度无统计学显著差异。
- CPoint吸湿膨胀产生的压力或热垂直加压均未增强硅酸钙基封闭剂的渗透深度。
- 封闭剂渗入牙本质小管与充填技术无关。
核心结论
- CPoint的吸湿膨胀产生的压力或热垂直加压均未增强硅酸钙基封闭剂的渗透深度。
- 封闭剂渗入牙本质小管与充填技术无关。
研究设计与样本
- 离体研究:100颗拔除的人恒前牙行根管预备,等分为3个实验组和1个对照组。
- 实验组为CPoint单尖法(CPSC)、牙胶单尖法(GPSC)、牙胶垂直加压法(GPVC),均使用硅酸钙基封闭剂与钙指示剂Fluo-3。
- 对照组为CPoint单尖法加钙指示剂Fluo-3但不使用封闭剂(CPF3)。
- 牙根轴向横切,于共聚焦激光扫描显微镜×10和×20放大下检查,以荧光测量最大渗透深度及12、3、6、9点钟4个环周位点深度。
主要发现
- 平均最大深度:CPSC 283.83 μm,GPSC 318.66 μm,GPVC 313.03 μm,3组间P = .7553,无统计学显著差异。
- 所有位点平均深度:CPSC 111.24 μm,GPSC 135.38 μm,GPVC 126.62 μm,3组间P = .5304,无统计学显著差异。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to investigate the depths of penetration of a calcium silicate-based sealer in dentinal tubules by using 3 different obturation methods. METHODS: One hundred extracted human permanent anterior teeth were endodontically prepared and divided equally into 3 experimental groups and 1 control group as follows: CPoint single cone (CPSC), gutta-percha single cone (GPSC), gutta-percha vertical condensation (GPVC), all with a calcium silicate-based sealer and calcium indicator Fluo-3, and CPoint single cone with a calcium indicator Fluo-3 (CPF3) without sealer as the control. The roots of the teeth in each group were axially cross-sectioned, and the surfaces were examined under confocal laser scanning microscopy at ×10 and ×20 magnifications. The sealer penetration depths were measured at their maximum depths and at 4 circumferential depths (12, 3, 6, and 9 o'clock) by using fluorescence. RESULTS: Statistical analyses by using one-way analysis of variance and repeated measures analysis with linear mixed models showed no statistically significant difference among the mean maximum depth measurements (CPSC, 283.83 μm; GPSC, 318.66 μm; and GPVC, 313.03 μm; P = .7553) and among the average depths across all points (CPSC, 111.24 μm; GPSC, 135.38 μm; and GPVC, 126.62 μm; P = .5304) for the 3 experimental groups. CONCLUSIONS: The pressure derived from hygroscopic expansion of CPoint or warm vertical condensation did not enhance penetration depths of the calcium silicate-based sealer. Sealer penetration into the dentinal tubules occurred independent of the obturation technique.
引用
- Jeong JW, DeGraft-Johnson A, Dorn SO, et al. Dentinal Tubule Penetration of a Calcium Silicate-based Root Canal Sealer with Different Obturation Methods. J Endod. 2017. PMID: 28216267. doi:10.1016/j.joen.2016.11.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。