微型猪上颌骨种植体骨结合的三维显微CT与二维组织形态计量学对比分析
研究将54枚植入14只微型猪上颌骨的种植体在28天和56天两个时间点进行三维显微CT与二维组织形态计量学对比,发现两者在骨种植体接触(BIC)及内环、外环区域均呈强相关(r=0.83–0.88,p<0.0001),靠近种植体处显微CT值高于组织形态计量学,结论认为每枚种植体3–4张组织切片似可预测三维BIC,而显微CT因非破坏性三维特性可能更具优势。
要点
- 显微CT与组织形态计量学在BIC(r=0.83)、内环(r=0.88)、外环(r=0.88)均强相关。
- 靠近种植体处显微CT测得的BIC值高于组织形态计量学。
- 每枚种植体3–4张组织切片似乎可预测三维BIC,显微CT可能因非破坏性三维特性更具优势。
核心结论
- 每枚种植体3–4张组织切片似乎可预测三维BIC,显微CT可能因非破坏性三维特性更具优势。
- 愈合时间可能不影响显微CT与组织形态计量学之间的可比性。
研究设计与样本
- 研究评估了54枚植入14只微型猪上颌骨的种植体。
- 选择两个不同时间点(28天和56天)评估三维BIC(距种植体2–5体素)、内环(6–30体素)和外环(55–100体素),使用显微CT(体素大小10 μm)并与组织形态计量学值进行相关性分析。
主要发现
- 显微CT与组织形态计量学在BIC上呈强相关(p<0.0001;28天r=0.84,56天r=0.85,总计r=0.83)。
- 内环强相关(p<0.0001;28天r=0.87,56天r=0.87,总计r=0.88)。
- 外环强相关(p<0.0001;28天r=0.85,56天r=0.85,总计r=0.88)。
- 靠近种植体处,显微CT值高于组织形态计量学。
关键数值与推荐
- 三维BIC评估距离种植体2–5体素,内环6–30体素,外环55–100体素。
- 显微CT体素大小为10 μm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: The bone implant contact (BIC) has traditionally been evaluated with histological methods. Thereupon, strong correlations of two-dimensional (2D) BIC have been detected between μCT and destructive histology. However, due to the high intra-sample variability in BIC values, one histological slice is not sufficient to represent 3D BIC. Therefore, our aim has been to correlate the averaged values of 3-4 histological sections to 3D μCT. MATERIAL AND METHODS: Fifty-four implants inserted into the maxilla of 14 minipigs were evaluated. Two different time points were selected to assess the 3D BIC (distance to implant: 2-5 voxels), an inner ring (6-30 voxels) and an outer ring (55-100 voxels) using μCT (voxel size: 10 μm) and to correlate the values to histomorphometry. RESULTS: Strong correlations (p < 0.0001; 28 days, 56 days, total) were seen between μCT and histomorphometry concerning BIC (r = 0.84, r = 0.85, r = 0.83), the inner ring (r = 0.87, r = 0.87, r = 0.88) and the outer ring (r = 0.85, r = 0.85, r = 0.88). Closer to the implant, μCT values were higher compared with histomorphometry. CONCLUSION: Although 3-4 histological slices per implant seem to predict the 3D BIC, μCT might be advantageous because of its non-destructive 3D character. The healing time may not impact on the comparability.