钛表面血小板诱导的上皮附着功能抑制微生物定植
本研究为体外研究,在经蛋白酶激活受体4激活肽(PAR4-AP)修饰的钛表面用富血小板血浆(PRP)诱导血小板聚集并释放IV型胶原,再接种人牙龈上皮细胞形成上皮片。将表达绿色荧光蛋白(GFP)的大肠埃希菌接种于有或无上皮片的PAR4-AP修饰钛表面,结果显示无上皮片处细菌密集聚集,有上皮片处仅见少量细菌,且未见细菌侵入上皮片与钛表面界面。
要点
- PAR4-AP修饰钛表面经PRP孵育后,聚集的血小板释放IV型胶原(基底板关键成分)。
- 上皮片存在时PAR4-AP钛表面仅见少量大肠埃希菌,无上皮片时细菌密集聚集。
- 未见细菌侵入上皮片与钛表面界面。
核心结论
- 作者认为这些体外结果说明血小板诱导的上皮屏障能有效防止PAR4-AP修饰钛表面的细菌附着、穿透和侵入。
研究设计与样本
- 体外研究:钛表面经PAR4-AP修饰后与富血小板血浆(PRP)孵育,再接种人牙龈上皮细胞形成上皮片,并以表达绿色荧光蛋白(GFP)的大肠埃希菌进行细菌定植实验。
主要发现
- 聚集的血小板在PAR4-AP修饰钛表面释放IV型胶原,人牙龈上皮细胞在该表面形成上皮片。
- 无上皮片的PAR4-AP钛表面大肠埃希菌密集聚集,有上皮片的PAR4-AP表面仅见少量大肠埃希菌。
- 未观察到细菌侵入上皮片与钛表面的界面。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The aim of this study was to evaluate the barrier function of platelet-induced epithelial sheets on titanium surfaces. The lack of functional peri-implant epithelial sealing with basal lamina (BL) attachment at the interface of the implant and the adjacent epithelium allows for bacterial invasion, which may lead to peri-implantitis. Although various approaches have been reported to combat bacterial infection by surface modifications to titanium, none of these have been successful in a clinical application. In our previous study, surface modification with protease-activated receptor 4-activating peptide (PAR4-AP), which induced platelet activation and aggregation, was successful in demonstrating epithelial attachment via BL and epithelial sheet formation on the titanium surface. We hypothesized that the platelet-induced epithelial sheet on PAR4-AP-modified titanium surfaces would reduce bacterial attachment, penetration, and invasion. Titanium surface was modified with PAR4-AP and incubated with platelet-rich plasma (PRP). The aggregated platelets released collagen IV, a critical BL component, onto the PAR4-AP-modified titanium surface. Then, human gingival epithelial cells were seeded on the modified titanium surface and formed epithelial sheets. Green fluorescent protein (GFP)-expressing Escherichia coli was cultured onto PAR4-AP-modified titanium with and without epithelial sheet formation. While Escherichia coli accumulated densely onto the PAR4-AP titanium lacking epithelial sheet, few Escherichia coli were observed on the epithelial sheet on the PAR4-AP surface. No bacterial invasion into the interface of the epithelial sheet and the titanium surface was observed. These in vitro results indicate the efficacy of a platelet-induced epithelial barrier that functions to prevent bacterial attachment, penetration, and invasion on PAR4-AP-modified titanium.
引用
- Maeno M, Lee C, Kim DM, et al. Function of Platelet-Induced Epithelial Attachment at Titanium Surfaces Inhibits Microbial Colonization. J Dent Res. 2017. PMID: 28086031. doi:10.1177/0022034516688888
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。