银纳米粒子、光动力疗法、二极管激光或激光激活纳米粒子消除根管内粪肠球菌:一项体外研究
本研究比较银纳米粒子(AgNPs)、810 nm二极管激光(DL)、使用吲哚菁绿(ICG)光敏剂的传统光动力疗法(PDT)及使用AgNPs的改良PDT对接种粪肠球菌的根管消毒效果。结果显示所有组粪肠球菌菌落数均显著减少(P < .05),其中AN/ICG/DL组减少最多(99.12%),但与DL组(97.41%)、AN组(94.42%)及对照组(94.61%)的差异无统计学意义(P > .05)。
要点
- 所有干预组及对照组的粪肠球菌菌落数均显著减少(P < .05)。
- AN/ICG/DL组菌落减少最多(99.12%),但与DL、AN及对照组差异无统计学意义(P > .05)。
- ICG-PDT、810 nm二极管激光和AgNPs有潜力作为根管系统消毒的辅助手段。
核心结论
- 使用ICG的PDT、810 nm二极管激光和AgNPs有潜力作为根管系统消毒的辅助手段。
研究设计与样本
- 体外研究,使用65颗拔除的人单根牙,根管预备后接种粪肠球菌培养4周,随机分为4个实验组和1个对照组(n = 9)。
主要发现
- 所有组粪肠球菌菌落数均显著减少(P < .05)。
- AN/ICG/DL组菌落数减少最多(99.12%),但与DL组(97.41%)、AN组(94.42%)及对照组(94.61%)的差异无统计学意义(P > .05)。
关键数值与推荐
- DL组:810 nm二极管激光照射(1 W,4次,每次10秒)。
- AN组:5 mL AgNPs(100 ppm)冲洗5分钟。
- ICG/DL组:ICG(1 mg/mL)/810 nm二极管激光(200 mW,30秒)传统PDT。
- AN/ICG/DL组:AgNPs/ICG/810 nm二极管激光(200 mW,30秒)改良PDT。
- 对照组:5 mL 2.5%次氯酸钠冲洗5分钟(n = 9)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to compare the efficacy of silver nanoparticles (AgNPs), an 810-nm diode laser (DL), conventional photodynamic therapy (PDT) with the use of indocyanine green (ICG) photosensitizer, and modified PDT with the use of AgNPs for the disinfection of root canals inoculated with Enterococcus faecalis. METHODS: The root canals of 65 extracted human single-rooted teeth were prepared, and E. faecalis was incubated in the root canals for 4 weeks. The teeth were then randomly divided into the following 4 experimental groups: the DL group: 810-nm DL irradiation (1 W, 4 times for 10 seconds), the AN group: 5 minutes of irrigation with 5 mL AgNPs (100 ppm), the ICG/DL group: conventional PDT with ICG (1 mg/mL)/810-nm DL (200 mW, 30 seconds), and the AN/ICG/DL group: modified PDT with AgNPs/ICG/810-nm DL (200 mW, 30 seconds). There was also a control group, which consisted of 5 minutes of irrigation with 5 mL 2.5% sodium hypochlorite (n = 9). Samples were obtained from dentin chips before and after the interventions. A reduction in colony count was assessed by counting the colony-forming units. RESULTS: Significant reductions were noted in E. faecalis colony counts in all groups (P < .05). The greatest reduction in colony count (99.12%) was noted in the AN/ICG/DL group (AgNPs/ICG/810-nm diode laser); however, the differences in this respect between the AN/ICG/DL group and the DL (97.41%), AN (94.42%), and control groups (94.61%) were not significant (P > .05). CONCLUSIONS: PDT with ICG, an 810-nm diode laser, and AgNPs has the potential to be used as an adjunct for disinfection of the root canal system.
引用
- Afkhami F, Akbari S, Chiniforush N, et al. Entrococcus faecalis Elimination in Root Canals Using Silver Nanoparticles, Photodynamic Therapy, Diode Laser, or Laser-activated Nanoparticles: An In Vitro Study. J Endod. 2016. PMID: 28027821. doi:10.1016/j.joen.2016.08.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。