新型机械冲洗剂搅动装置对下颌磨牙近中根管及峡部碎屑清除效果的比较
研究将50颗下颌磨牙近中根 embedded 于环氧树脂并切片,比较连续旋转 Easy Clean、往复运动 Easy Clean、被动超声冲洗(PUI)、Endoactivator 与常规冲洗对根管及峡部碎屑的清除效果。结果显示三次20秒冲洗液激活方案清洁效果更好;连续旋转 Easy Clean 在2 mm根管处优于常规冲洗,在峡部三个水平优于常规冲洗、在4 mm处优于 Endoactivator,PUI 在6 mm处优于常规冲洗。
要点
- 三次20秒冲洗液激活方案比单次或两次激活更能清洁根管和峡部。
- 连续旋转 Easy Clean 在根管2 mm处碎屑清除优于常规冲洗(P < .05)。
- 峡部连续旋转 Easy Clean 在3个水平优于常规冲洗、在4 mm处优于 Endoactivator(P < .05)。
核心结论
- 冲洗液激活方法能改善根管和峡部的清洁效果,尤其是连续旋转使用的 Easy Clean。
- 三次20秒冲洗液激活方案有利于获得更好的清洁效果。
研究设计与样本
- 将50颗下颌磨牙近中根用金属套匣包埋于环氧树脂中,并在距根尖2、4、6 mm处切片。
- 根管预备后将样本分为5组(n = 10),分别采用连续旋转 Easy Clean、往复运动 Easy Clean、被动超声冲洗(PUI)、Endoactivator 和常规冲洗进行最终冲洗方案。
主要发现
- 三次20秒冲洗液激活方案对根管和峡部的清洁效果更好。
- 所有步骤完成后,根管分析仅在2 mm处显示统计学差异,连续旋转 Easy Clean 比常规冲洗更有效(P < .05)。
- 所有步骤完成后,峡部差异最大:连续旋转 Easy Clean 在分析的3个水平均比常规冲洗更有效,且在4 mm处比 Endoactivator 更有效(P < .05)。
- PUI 在6 mm处比常规冲洗清洁效果更好(P < .05)。
- 连续旋转 Easy Clean、往复运动 Easy Clean 和 PUI 之间无统计学差异(P > .05)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to compare the effectiveness of Easy Clean (Easy Dental Equipment, Belo Horizonte, MG, Brazil) in continuous and reciprocating motion, passive ultrasonic irrigation (PUI), Endoactivator systems (Dentsply Maillefer, Ballaigues, Switzerland), and conventional irrigation for debris removal from root canals and isthmus. METHODS: Fifty mesial roots of mandibular molars were embedded in epoxy resin using a metal muffle; afterward, the blocks containing the roots were sectioned at 2, 4, and 6 mm from the apex. After instrumentation, the roots were divided into 5 groups (n = 10) for application of the final irrigation protocol using Easy Clean in continuous rotation, Easy Clean in reciprocating motion, PUI, Endoactivator, and conventional irrigation. Scanning electron microscopic images were taken after instrumentation and after the first, second, and third activation of irrigating solution to evaluate the area of remaining debris with image J software (National Institutes of Health, Bethesda, MD). RESULTS: The protocol of 3 irrigating solution activations for 20 seconds provided better cleaning of the canal and isthmus. On conclusion of all procedures, analysis of the canals showed a statistical difference only at 2 mm; the Easy Clean in continuous rotation was more efficient than conventional irrigation (P < .05). On conclusion of all steps, the largest difference was observed in the isthmus in which the Easy Clean in continuous rotation was more effective than conventional irrigation at the 3 levels analyzed and the Endoactivator at 4 mm (P < .05). The PUI promoted greater cleaning than conventional irrigation at 6 mm (P < .05). There was no statistical difference between Easy Clean in continuous rotation, Easy Clean in reciprocating motion, and PUI (P > .05). CONCLUSIONS: Irrigating solution activation methods provided better cleaning of the canal and isthmus, especially the Easy Clean used in continuous rotation. The protocol of 3 irrigating solution activations for 20 seconds favored better cleaning.
引用
- Duque JA, Duarte MA, Canali LC, et al. Comparative Effectiveness of New Mechanical Irrigant Agitating Devices for Debris Removal from the Canal and Isthmus of Mesial Roots of Mandibular Molars. J Endod. 2016. PMID: 27989584. doi:10.1016/j.joen.2016.10.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。