锥形束CT滤过器对模拟牙髓并发症诊断的影响

Influence of Cone-Beam Computed Tomography filters on diagnosis of simulated endodontic complications.
PubMed 文献 · Int Endod J · 2017-01-19

研究用16颗人牙在3个下颌骨中模拟根管锉折断、根管壁穿孔、铸造桩偏移和牙根外吸收,由5名口腔放射科医师在有/无XoranCat软件滤过器下独立评估锥形束CT图像,计算准确率、敏感度和特异度并比较ROC曲线下面积。结果显示各滤过器均未改善上述模拟牙髓并发症的诊断,其中根管锉折断最难诊断。

要点

  • 各滤过器组ROC曲线下面积无差异,滤过器未改善模拟牙髓并发症诊断。
  • 根管锉折断最难诊断,其次为根管壁穿孔、牙根外吸收和铸造桩偏移。
  • 仅根管锉折断组中全部滤过器与金标准及原始图像比较差异有统计学意义(P=0.00)。

核心结论

  • 滤过器未改善所评估的模拟牙髓并发症的诊断,其诊断在临床实践中仍是重大挑战。

研究设计与样本

  • 在3个下颌骨的16颗人牙上模拟根管锉折断(G1)、根管壁穿孔(G2)、铸造桩偏移(G3)和牙根外吸收(G4),行锥形束CT检查(I-Cat Next Generation)。
  • 由5名口腔放射科医师分别在有和无XoranCat软件滤过器条件下独立评估图像,计算准确率、敏感度和特异度,并行ROC曲线分析和McNemar检验(P<0.05)。

主要发现

  • G1是最难诊断的牙髓并发症,其次为G2、G4和G3。
  • 各滤过器组ROC曲线下面积无差异;G1最佳为Sharpen Super Mild滤过器(0.47),G2最佳为Angio Sharpen Low 3×3(0.93),G3最佳为Angio Sharpen Low 3×3、S9、Shadow和Sharpen(1.00),G4最佳为Sharpen 3×3(1.00)。
  • McNemar检验显示仅G1组中全部滤过器与金标准比较(全部滤过器P=0.00)及与原始图像比较(全部滤过器P=0.00)差异有统计学意义,其余组无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the influence of cone-beam computed tomography (CBCT) filters on diagnosis of simulated endodontic complications. METHODOLOGY: Sixteen human teeth, in three mandibles, were submitted to the following simulated endodontic complications: (G1) fractured file, (G2) perforations in the canal walls, (G3) deviated cast post, and (G4) external root resorption. The mandibles were submitted to CBCT examination (I-Cat® Next Generation). Five oral radiologists evaluated the images independently with and without XoranCat® software filters. Accuracy, sensitivity and specificity were determined. ROC curves were calculated for each group with the filters, and the areas under the curves were compared using anova (one-way) test. McNemar test was applied for pair-wise agreement between all images versus the gold standard and original images versus images with filters (P < 0.05). RESULTS: G1 was the most difficult endodontic complication to diagnosis, followed by G2, G4 and G3. There were no differences between areas under the ROC curves for the filters in all groups; however, Sharpen Super Mild filter had the best results for G1 (0.47), Angio Sharpen Low 3 × 3 for G2 (0.93), Angio Sharpen Low 3 × 3, S9, Shadow and Sharpen for G3 (1.00) and Sharpen 3 × 3 for G4 (1.00). The McNemar test revealed significant differences between all filters with the gold standard (P = 0.00 for all filters) and the originals images (P = 0.00 for all filters) only in G1 group. There were no differences in the other groups. CONCLUSIONS: The filters did not improve the diagnosis of the simulated endodontic complications evaluated. Their diagnosis remains a major challenge in clinical practice.