计算机辅助模拟与牙模正颌手术治疗下颌前突及面部不对称患者的比较
回顾性纳入60例下颌前突伴面部不对称患者,比较计算机辅助模拟与牙模手术两组术后上颌咬合平面、下颌咬合平面及下颌体平面的横滚角与偏航角差异。计算机辅助模拟组在多个下颌平面角度纠正上较牙模手术组更明显,但上颌咬合平面偏航角与横滚角组间差异无统计学意义。结论认为计算机辅助模拟纠正下颌不对称较牙模手术更有效。
要点
- 计算机辅助模拟组下颌咬合平面偏航角0.84°±0.36° vs 牙模组0.36°±0.48°(P=0.043)。
- 计算机辅助模拟组下颌咬合平面横滚角0.54°±0.40° vs 牙模组0.26°±0.79°(P=0.032)。
- 上颌咬合平面偏航角与横滚角两组差异无统计学意义(P>0.05)。
核心结论
- 计算机辅助模拟纠正下颌不对称较牙模手术更有效。
研究设计与样本
- 回顾性研究纳入60例下颌前突伴面部不对称患者,分为计算机辅助模拟组(Ⅰ组)与牙模手术组(Ⅱ组)。
主要发现
- 下颌咬合平面偏航角牙模手术组0.36°±0.48° vs 计算机辅助模拟组0.84°±0.36°(P=0.043)。
- 下颌咬合平面横滚角牙模手术组0.26°±0.79° vs 计算机辅助模拟组0.54°±0.40°(P=0.032)。
- 下颌体平面偏航角牙模手术组0.60°±1.04° vs 计算机辅助模拟组0.23°±0.52°(P=0.008)。
- 下颌体平面横滚角牙模手术组0.82°±0.72° vs 计算机辅助模拟组0.53°±0.37°(P=0.028)。
- 上颌咬合平面偏航角与横滚角两组差异无统计学意义(P>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To evaluate the results of the orthognathic surgery with computer aided simulation-three-dimensional(3D) printed surgical guide and dental model surgery in the treatmemt of patients with mandibular excess and facial asymmetries. Methods: The coordinate system was built in ProPlan CMF 2.0 software, and the horizontal plane consisted of PoL, PoR, OrL, middle sagittal plane through nasion point and basion point and the plane perpendicular to the horizontal plane, coronoid plane through nasion point and the plane perpendicular to the horizontal plane and middle sagittal plane. The orientation of maxilla and mandibular distal segment was calculated by each triangle(U1-U6L-U6R, L1-L6L-L6R, Me-M5L-M5R) before and after orthognathic surgery. A total of 60 mandibular excess patients with facial asymmetries were enrolled in this retrospective study. They were divided into two groups, group Ⅰ with computer aided simulation, group Ⅱ with dental model surgery. The difference of maxillary occlusal plane roll and yaw angle, mandibular occlusal plane roll and yaw angle, and mandibular body plane roll and yaw angle were calculated. Statistical analysis was performed with SPSS 17.0 software. Results: The yaw angle of mandibular occlusal plane of the dental model surgery and computer aided simulation was 0.36°± 0.48° and 0.84° ± 0.36° (P=0.043), respectively. The roll angle of mandibular occlusal plane of the dental model surgery and computer aided simulation was 0.26°±0.79° and 0.54°±0.40°(P=0.032), respectively. The yaw angle of mandibular body plane of the dental model surgery and computer aided simulation was 0.60°± 1.04° and 0.23°±0.52°(P=0.008), respectively. The roll angle of mandibular body plane of the dental model surgery and computer aided simulation was 0.82° ± 0.72° and 0.53° ± 0.37° (P=0.028), respectively. The changes in computer aided simulation group were more obvious than that in the dental model surgery group, but the difference was not significant in the yaw angle of maxillary occlusal plane and the roll angle of maxillary occlusal plane between the two groups(P >0.05). Conclusions: It was more effective to correct mandibular asymmetry by computer aided simulation than dental model surgery.
引用
- Shen SY, Chen TT, Lu CP, et al. [Comparison between computer aided simulation and dental model orthognathic surgery for the treatment of patients with mandibular excess and facial asymmetries]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2016. PMID: 27806756. doi:10.3760/cma.j.issn.1002-0098.2016.11.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。