文献速递口腔修复与种植

验证实际微动值作为愈合后种植体微动度(继发性种植体稳定性)直接测量指标的价值:一项体内组织学与生物力学研究

Validation of value of actual micromotion as a direct measure of implant micromobility after healing (secondary implant stability). An in vivo histologic and biomechanical study.
PubMed 文献 · Clin Oral Implants Res · 2016-01-04

在24枚植入羊髂嵴的种植体上,于2个月后处死动物取骨块,测量实际微动值(VAM)并与种植体稳定性商值(ISQ)、反向扭矩值(RTV)、骨-种植体接触百分比(%BIC)、骨体积百分比(%BV)及嵴顶骨吸收(CBL)进行相关性分析。结果显示VAM与RTV、%BIC、ISQ及CBL显著相关(P < 0.05)。作者认为VAM可用于临床检查种植体骨结合程度、继发性稳定性及CBL,但需未来研究证实,且测量口腔内VAM的仪器尚待开发。

要点

  • 羊髂嵴模型2个月时VAM与RTV、%BIC、ISQ及CBL显著相关(P < 0.05)。
  • 作者认为VAM可用于临床检查种植体骨结合程度、继发性稳定性及CBL。
  • 作者指出需未来研究证实结果,且口腔内VAM测量仪器尚待开发。

核心结论

  • VAM与其他骨结合参数存在统计学相关性,作者认为其可用于临床检查种植体骨结合程度、继发性稳定性及CBL,但需未来研究证实,且口腔内VAM测量仪器尚待开发。

研究设计与样本

  • 将24枚3.8 × 11.5 mm种植体(Dynamix, Cortex, Shlomi, Israel)植入羊髂嵴,2个月后处死动物,取新鲜骨块固定于定制装置计算VAM,并测量ISQ、RTV、%BIC、%BV及CBL,分析VAM与其他参数的相关性。

主要发现

  • VAM与RTV、%BIC、ISQ及CBL显著相关(P < 0.05)。

关键数值与推荐

  • VAM与RTV、%BIC、ISQ及CBL的相关系数原文未报告。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需未来研究证实这些结果。
  • 作者指出测量口腔内VAM的仪器尚待开发。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The osseointegration process replaces the surgically damaged bone with newly formed bone in contact to the implant surface. This involves some loss of primary stability, which will continue until new bone is formed providing a new stability, known as "secondary stability." A direct measurement of secondary implant stability appears fundamental to determine the period and modalities for implant loading. The aim of this study was to validate the measurement of the implant micromotion to test secondary implant stability. MATERIALS AND METHODS: Twenty-four 3.8 × 11.5 mm implants (Dynamix, Cortex, Shlomi, Israel) were inserted in sheep iliac crests. The animals were sacrificed after 2 months, and the freshly retrieved bone blocks were immediately fixed on a customized device to calculate the value of actual micromotion (VAM) according to a previously described technique. Implant stability quotient (ISQ) values, reverse torque value (RTV), %bone-to-implant contact (%BIC), bone volume percentage (%BV) and crestal bone loss (CBL) were also calculated for each implant. Statistical correlations between VAM and the other parameters were calculated. RESULTS: Data correlation analysis between the examined parameters showed that VAM significantly correlates (P < 0.05) to RTV, %BIC, ISQ and CBL. CONCLUSIONS: As VAM showed to be statistical correlated to the other parameters of osseointegration, it may be used to clinically check the amount of implant osseointegration, secondary stability and CBL. Future studies are needed to confirm these results moreover. An instrument to measure VAM in the oral cavity still needs to be developed.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Trisi P, Berardini M, Falco A, et al. Validation of value of actual micromotion as a direct measure of implant micromobility after healing (secondary implant stability). An in vivo histologic and biomechanical study. Clin Oral Implants Res. 2016. PMID: 26727557. doi:10.1111/clr.12756

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。