3D打印、种植体宏观设计与牙槽嵴形态对静态计算机辅助种植手术精度和初期稳定性的影响:一项体外研究
本体外研究评估了DLP与ME打印导板对sCAIS位置精度的影响,并比较了两种组织水平种植体(Straumann TLC、TLX)在愈合前磨牙区与磨牙拔牙区的插入扭矩和ISQ。结果显示愈合前磨牙区偏差更小,打印技术不影响精度但ME导板IT较低,TLC偏差更大但ISQ和IT更高。
要点
- 愈合前磨牙区的角度、嵴顶和根尖偏差均显著小于磨牙拔牙区(p<0.01)。
- DLP与ME打印导板的位置精度无显著差异,但ME导板插入扭矩较低。
- TLC种植体偏差大于TLX,但ISQ(81.58±6.03 vs 77.18±5.18)和IT更高。
核心结论
- 体外条件下DLP与ME打印导板位置精度无显著差异。
- TLC种植体获得更高IT和ISQ但偏差大于TLX。
- 愈合前磨牙区偏差小于磨牙拔牙区。
研究设计与样本
- 通过叠加术前术后扫描确定角度、嵴顶和根尖偏差,记录IT和ISQ。
- 采用三因素方差分析、对齐秩变换方差分析和有序逻辑回归进行统计分析。
主要发现
- 愈合前磨牙区角度偏差2.35±1.36°、嵴顶偏差0.50±0.20 mm、根尖偏差0.86±0.41 mm,均小于磨牙拔牙区的3.33±1.62°、0.75±0.36 mm、1.33±0.63 mm(p<0.01)。
- 打印技术不影响精度,但ME导板显示较低的IT。
- TLC偏差大于TLX,但ISQ更高(81.58±6.03 vs 77.18±5.18;p<0.01)且IT更高。
临床怎么用
- ME打印导板在体外精度与DLP相当,但临床等效性需体内研究确认。
- 磨牙拔牙区应预期更大偏差,需预留足够安全边缘。
- 种植体宏观设计对精度和初期稳定性的影响方向相反,需权衡选择。
局限性
- 本研究为体外研究,结果需临床体内研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To assess the positional accuracy of static computer-assisted implant surgery (sCAIS) using guides printed by digital light processing (DLP) or material extrusion (ME), and to compare insertion torque (IT) and implant stability quotient (ISQ) of two tissue-level implants (Straumann TLC, TLX) in healed premolar ridges versus molar extraction sites in vitro. METHODS: Eighty implants were placed in standardized resin bone models using DLP- or ME-printed guides. Angular, crestal, and apical deviations were determined by superimposing preoperative and postoperative scans; IT and ISQ were recorded. Statistical analysis was performed with three-way ANOVA, aligned rank transform ANOVA and ordinal logistic regression. RESULTS: Healed premolar ridges showed smaller angular (2.35 ± 1.36° vs. 3.33 ± 1.62°), crestal (0.50 ± 0.20 vs. 0.75 ± 0.36 mm), and apical deviations (0.86 ± 0.41 vs. 1.33 ± 0.63 mm) than molar extraction sites (p<0.01). Printing technology did not affect accuracy, but ME guides showed lower IT. TLC deviated more than TLX but reached higher ISQ (81.58 ± 6.03 vs. 77.18 ± 5.18; p<0.01) and IT. CONCLUSIONS: In vitro, DLP and ME guides showed no significant difference in positional accuracy. TLC achieved higher IT and ISQ but greater deviation than TLX. Deviations were smaller at healed premolar ridges than at molar extraction sites. CLINICAL SIGNIFICANCE: ME-printed guides showed accuracy comparable to DLP-printed guides in vitro, however clinical equivalence requires in vivo confirmation. Larger deviations should be anticipated at molar extraction sites, with adequate safety margins. Implant macro-design affected accuracy and primary stability in opposite directions.