文献速递口腔修复与种植

咬肌体积与横截面积作为种植体晚期机械失败危险因素的匹配病例对照研究

Masseter Muscle Volume and Cross-Sectional Area as Risk Factors for Late Mechanical Dental Implant Failure: A Matched Case-Control Study.
PubMed 文献 · Clin Oral Implants Res · 2026-10-19

本研究为1:4匹配病例对照研究,纳入23例种植体晚期机械失败(基台、螺丝或种植体折断)与92例成功对照,按性别、年龄(±10岁)、解剖位置及维护期(±2年)匹配。通过CBCT三维重建量化咬肌形态,多变量GEE模型显示咬肌体积每增加1000 mm3失败风险增1.24倍,CSA每增加10 mm2增1.11倍;ROC曲线下面积分别为0.846和0.871,并提出初步风险分层截断值。

要点

  • 咬肌体积与横截面积增大与种植体晚期机械失败风险显著相关(p<0.001)。
  • 咬肌体积每增1000 mm3,机械失败风险增加1.24倍;CSA每增10 mm2,风险增加1.11倍。
  • 初步截断值:体积31,272.56 mm3(敏感度86.96%,特异度77.17%),CSA 691.30 mm2(敏感度82.61%,特异度79.35%)。

核心结论

  • 较大的咬肌体积和横截面积与种植体晚期机械失败显著相关,可作为初步风险分层参考,但结论为探索性,需前瞻性验证。

研究设计与样本

  • 1:4匹配病例对照研究,纳入23例种植体晚期机械失败(基台、螺丝或种植体折断)和92例成功对照。
  • 按性别、年龄(±10岁)、解剖位置和维护期(±2年)匹配。
  • 采用锥形束CT(CBCT)三维重建量化咬肌体积和横截面积。
  • 使用多变量广义估计方程(GEE)模型分析独立危险因素。

主要发现

  • 咬肌体积每增加1000 mm3,机械失败风险增加1.24倍。
  • 咬肌横截面积每增加10 mm2,机械失败风险增加1.11倍。
  • ROC曲线下面积:咬肌体积0.846,横截面积0.871;内部Bootstrap验证的AUC 95%置信区间分别为0.751–0.931和0.767–0.951。

关键数值与推荐

  • 咬肌体积最大约登指数截断值为31,272.56 mm3,敏感度86.96%,特异度77.17%。
  • 咬肌横截面积最大约登指数截断值为691.30 mm2,敏感度82.61%,特异度79.35%。

临床怎么用

  • 对于咬肌体积或横截面积较大的患者,可考虑作为种植体晚期机械失败的初步风险分层参考,但尚不能常规用于临床决策。

局限性

  • 本研究为探索性研究,样本量有限(23例失败病例),需在独立队列中前瞻性验证所提出的截断值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to investigate whether three-dimensional (3D) masseter muscle morphology-volume and cross-sectional area (CSA)-is associated with the risk of late mechanical dental implant failure and to derive preliminary cut-off values for risk stratification. MATERIAL AND METHODS: This 1:4 matched case-control study investigated 23 cases of late mechanical failure (fixture fracture, screw fracture, or abutment fracture) and 92 successful controls. Participants were matched by gender, age (±10 years), anatomical location, and maintenance period (±2 years). Masseter morphology was quantified using the 3D reconstruction of the cone-beam computed tomography (CBCT) data. Independent risk factors were determined using a multivariable generalized estimating equation model adjusting for potential confounders. RESULTS: Increased masseter muscle bulk was significantly associated with mechanical failure (p < 0.001). The odds of mechanical failure increased by 1.24-fold per 1000 mm3 increase in masseter volume and by 1.11-fold per 10 mm2 increase in CSA. ROC analysis demonstrated AUCs of 0.846 for masseter volume and 0.871 for CSA. The maximum-Youden thresholds were 31,272.56 mm3 for volume and 691.30 mm2 for CSA, with sensitivities of 86.96% and 82.61% and specificities of 77.17% and 79.35%, respectively. Internal bootstrap validation yielded AUC 95% confidence intervals of 0.751-0.931 and 0.767-0.951, respectively. CONCLUSIONS: Greater masseter muscle volume and CSA were significantly associated with late mechanical implant failure in this matched case-control study. The proposed cut-off values may provide preliminary reference values for risk stratification. However, these findings should be regarded as exploratory and require prospective validation in independent cohorts before routine clinical implementation.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Choi HS, Lee EC, Pang EK, et al. Masseter Muscle Volume and Cross-Sectional Area as Risk Factors for Late Mechanical Dental Implant Failure: A Matched Case-Control Study. Clin Oral Implants Res. 2026. PMID: 42897882. doi:10.1111/clr.70188

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。