文献速递牙体牙髓病儿童口腔

氧化石墨烯量子点增强次氯酸钠抗菌活性并减轻对根尖乳头干细胞的细胞毒性

Graphene Oxide Quantum Dots Enhance Antibacterial Efficacy of Sodium Hypochlorite and Mitigate Cytotoxicity to Stem Cells From the Apical Papilla: An in Vitro Study.
PubMed 文献 · Int Endod J · 2026-10-13

本研究探讨氧化石墨烯量子点(GOQDs)能否在增强次氯酸钠(NaOCl)抗菌效果的同时减轻其对根尖乳头干细胞(SCAPs)的毒性。体外实验表明,GOQDs(50 μg/mL)联合NaOCl(1.5%)可增强对浮游菌及生物膜的抗菌和抗生物膜活性,并通过过氧化物酶样催化活性增强氧化降解,同时将NaOCl暴露后SCAPs的细胞活力从约3%恢复至15%,减少ROS过度产生。

要点

  • GOQDs联合NaOCl可增强对粪肠球菌和戈登链球菌浮游菌及单/多物种生物膜的抗菌活性。
  • GOQDs通过物理破坏细菌细胞膜和过氧化物酶样催化活性增强NaOCl的氧化降解。
  • GOQDs减轻NaOCl对SCAPs的细胞毒性,将细胞活力从约3%恢复至15%并减少ROS过度产生。

核心结论

  • GOQDs可同时增强NaOCl介导的生物膜清除并清除ROS以保护SCAPs免受氧化损伤,为再生牙髓治疗中消毒与再生的矛盾提供潜在策略。

研究设计与样本

  • 体外研究,评估GOQDs(50 μg/mL)联合NaOCl(1.5%)对粪肠球菌和戈登链球菌浮游菌及单/多物种生物膜的抗菌效果及对NaOCl暴露SCAPs的细胞保护作用。

主要发现

  • GOQDs增强了NaOCl对浮游菌和生物膜的抗菌及抗生物膜活性。
  • GOQDs物理破坏细菌细胞膜并通过过氧化物酶样催化活性增强NaOCl介导的氧化降解,亚甲蓝脱色法显示催化增强率为55.9%。
  • GOQDs未升高细菌胞内ROS水平,而是引起短暂ROS爆发后快速消耗。
  • GOQDs显著减轻NaOCl诱导的SCAPs细胞毒性,细胞活力从约3%(单用NaOCl)恢复至15%(联合组),并减少ROS过度产生。

关键数值与推荐

  • GOQDs使用浓度为50 μg/mL,NaOCl使用浓度为1.5%。
  • 催化增强率(亚甲蓝脱色法)为55.9%。
  • SCAPs细胞活力:单用NaOCl组约3%,联合组15%。

临床怎么用

  • GOQDs可作为辅助剂优化再生牙髓治疗的冲洗方案,在增强NaOCl消毒效果的同时保护SCAPs。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: Sodium hypochlorite (NaOCl) is considered the gold standard irrigant in regenerative endodontic therapy (RET) due to its potent antimicrobial activity. However, its clinical application presents a significant paradox: the concentrations required for effective debridement can cause irreversible cytotoxicity to stem cells from the apical papilla (SCAPs), while lower concentrations often fail to eliminate biofilms within the complex root canal system. Graphene oxide quantum dots (GOQDs) are zero-dimensional carbon-based nanomaterials with intrinsic peroxidase-like activity and reactive oxygen species (ROS) scavenging capabilities. This study investigated whether GOQDs could simultaneously enhance the antibacterial efficacy of NaOCl while mitigating its cytotoxic effects on SCAPs. METHODOLOGY: The antibacterial effect of GOQDs (50 μg/mL) combined with NaOCl (1.5%) was evaluated against planktonic bacteria and single-/multi-species biofilms of Enterococcus faecalis and Streptococcus gordonii using growth curve monitoring, colony-forming unit counting, crystal violet staining, CCK-8 assay and confocal laser scanning microscopy. The underlying mechanisms were investigated via scanning electron microscopy, SYTO 9/propidium iodide membrane integrity assay, DCFH-DA intracellular ROS detection and methylene blue decolorization assay. The cytoprotective effect of GOQDs on NaOCl-exposed SCAPs was assessed using CCK-8, live/dead staining and DCFH-DA ROS staining. RESULTS: GOQDs enhanced the antibacterial and anti-biofilm activity of NaOCl against both planktonic bacteria and biofilms. Mechanistically, GOQDs physically disrupted bacterial cell membranes and augmented NaOCl-mediated oxidative degradation via peroxidase-like catalytic activity, as evidenced by methylene blue decolorization (catalytic enhancement rate: 55.9%). Notably, GOQDs did not elevate bacterial intracellular ROS levels; instead, they enabled a transient ROS burst followed by rapid consumption. Furthermore, GOQDs significantly mitigated NaOCl-induced cytotoxicity in SCAPs, restoring cell viability from approximately 3% (NaOCl alone) to 15% (combination group) and reducing ROS overproduction. CONCLUSIONS: GOQDs offer a potential strategy to address the disinfection-regeneration conflict in RET by enhancing NaOCl-mediated biofilm eradication while simultaneously scavenging ROS to protect SCAPs from oxidative damage. This concentration-dependent dual functionality positions GOQDs as a promising adjunctive agent to optimise irrigation protocols and advance clinical outcomes in regenerative endodontic therapies.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Huang M, Zhao P, Dissanayaka WL, et al. Graphene Oxide Quantum Dots Enhance Antibacterial Efficacy of Sodium Hypochlorite and Mitigate Cytotoxicity to Stem Cells From the Apical Papilla: An in Vitro Study. Int Endod J. 2026. PMID: 42866927. doi:10.1111/iej.70292

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。