CAD/CAM二硅酸锂高嵌体在根管治疗后磨牙的五年临床性能:回顾性队列研究
该回顾性队列研究评估了CAD/CAM二硅酸锂高嵌体在根管治疗后磨牙上的五年临床性能,分析牙齿存活率、修复体存活率和修复体成功率。五年牙齿存活率98.4%(95%CI 89.3-99.8),修复体存活率100%,修复体成功率88.8%(95%CI 77.9-94.5)。结论认为二硅酸锂高嵌体可提供可预测的冠部覆盖,牙齿层面事件均为牙髓源性而非修复源性。
要点
- 二硅酸锂高嵌体五年修复体存活率100%,牙齿存活率98.4%。
- 修复体成功率88.8%,主要需重抛光或复合树脂修补。
- 牙齿层面失败均为牙髓再干预,与修复体无关。
核心结论
- 二硅酸锂高嵌体在根管治疗后磨牙上五年表现可预测,修复体存活率高。
- 牙齿层面事件均为牙髓源性,提示修复与生物学结局应作为独立终点报告。
研究设计与样本
- 63个修复体(59例患者)完成回访并分析,平均随访5.1年。
- 所有牙齿均因不可逆性牙髓炎治疗,无根尖周透射影。
主要发现
- 五年牙齿存活率98.4%(95%CI 89.3-99.8),无牙髓再干预生存率96.8%(95%CI 87.9-99.2)。
- 修复体存活率100%,无修复体被替换或脱落。
- 修复体成功率88.8%(95%CI 77.9-94.5),排除牙髓开髓后为90.4%。
- 12至60个月间共7次干预:4次重抛光、2次复合树脂修补、1次牙髓开髓。
- 24个月时发生2例牙齿层面事件:1例拔除、1例经高嵌体行牙髓再治疗。
关键数值与推荐
- 修复体成功定义为无任何干预,牙齿存活定义为牙齿保留(拔除为事件)。
- 两名校准检查者使用修订版FDI标准评估,加权kappa大于0.90。
- 无修复体在任何类别中被评为5级。
临床怎么用
- 对于剩余牙体组织足够的根管治疗后磨牙,高嵌体可作为全冠的保守替代方案。
- 分别报告修复体存活率和成功率有助于临床医生更现实地预估维护需求。
局限性
- 回顾性设计,仅63个修复体完成回访,样本量有限。
- 所有操作由同一操作者完成,结果可能受操作者经验影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the five-year clinical performance of CAD/CAM lithium disilicate overlays placed on endodontically treated molars, analysing tooth survival, restoration survival and restoration success as separate endpoints. MATERIALS AND METHODS: Ninety-three overlays placed between 2016 and 2021 were identified; 63 in 59 patients attended recall and were analysed. One operator performed all procedures. Every tooth had been treated for irreversible pulpitis without periapical radiolucency. Tooth survival was retention of the tooth (extraction as the event), restoration survival retention of the original restoration, and restoration success freedom from any intervention; nonsurgical retreatment was a separate tooth-level event. Two calibrated examiners graded performance with the revised FDI criteria before any intervention (weighted kappa > 0.90). Outcomes were estimated with the Kaplan-Meier method. RESULTS: Sixty-two of the 63 evaluable restorations were in function at five years (mean follow-up 5.1 years). Two tooth-level events occurred at 24 months, both endodontic: one extraction and one retreatment through the overlay. Five-year tooth survival was 98.4% (95% CI 89.3-99.8) and survival free of endodontic re-intervention 96.8% (95% CI 87.9-99.2). No restoration was replaced or lost (restoration survival 100%). Seven interventions were performed between 12 and 60 months: four refinishing, two composite repairs and one endodontic access. Kaplan-Meier restoration success was 88.8% (95% CI 77.9-94.5), or 90.4% excluding the endodontic access. No restoration was graded 5 in any category. CONCLUSIONS: Lithium disilicate overlays provided predictable coronal coverage of endodontically treated molars over five years. Both tooth-level events were endodontic rather than restorative, indicating that restorative and biological outcomes behave as separate endpoints. CLINICAL SIGNIFICANCE: Overlays may offer a conservative alternative to full crowns for endodontically treated molars with sufficient residual tooth structure. Reporting restoration survival and restoration success separately gives clinicians a more realistic picture of the maintenance such restorations are likely to require.
引用
- Erkan E, Gündoğar M, Özyürek T, et al. Five-year clinical performance of CAD/CAM lithium disilicate overlay restorations in endodontically treated molars: A retrospective cohort study. J Dent. 2026. PMID: 42826920. doi:10.1016/j.jdent.2026.107090
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。