文献速递口腔修复与种植口腔正畸

不同视角对口腔美学区缺陷检出正确率的影响

[Analysis of detection accuracy rate of dental esthetic defects under different visual angles].
PubMed 文献 · Zhonghua Kou Qiang Yi Xue Za Zhi · 2026-09-01

研究纳入114名口腔执业医师,以26岁女性上前牙基线像构建11张美学缺陷图像,经0°、90°、180°旋转得36张图片,每张展示8秒。结果显示0°视角检出正确率最高52.2%,90°最低26.8%,中切牙正确率54.2%显著高于其他牙位34.9%,专业背景无显著差异。

要点

  • 0°视角最利于美学缺陷识别,90°视角正确率最低。
  • 中切牙美学缺陷检出正确率显著高于其他牙位。
  • 修复正畸专业与其他专业医师检出正确率无显著差异。

核心结论

  • 视角显著影响口腔美学区缺陷检出正确率,0°视角更利于识别。
  • 牙位及缺陷类型对检出正确率存在影响。

研究设计与样本

  • 纳入2025年1至12月参加北京大学口腔医学院继续教育培训的114名口腔执业医师。
  • 分为修复和正畸专业组49名与其他专业组65名。
  • 以26岁女性上前牙基线像为对照,构建4类美学缺陷图像11张,共12张研究图像。
  • 每张图像经0°、90°、180°旋转后获得36张研究图片,通过幻灯片展示,每张8秒。
  • 采用卡方检验分析缺陷检出率与检出正确率。

主要发现

  • 36张图片缺陷检出率范围为23.7%(27/114)至100.0%(114/114)。
  • 检出正确率范围为5.3%(6/114)至79.8%(91/114)。
  • 切缘位置、龈缘位置、牙齿长轴及牙冠宽长比在不同视角下检出正确率差异均有统计学意义(均P<0.017)。

临床怎么用

  • 临床评价口腔美学缺陷时优先采用0°视角以提高检出正确率。
  • 应关注不同牙位和缺陷类型对检出正确率的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the effect of different visual angles on the accuracy of esthetic defect detection in the dental esthetic zone, clarify the differences in detection accuracy across different tooth positions, esthetic defect types and professional backgrounds of dentists, so as to provide reference for standardized clinical evaluation of dental esthetics. Methods: A total of 114 licensed dentists who participated in various continuing education programs at Peking University School and Hospital of Stomatology from January to December 2025 was enrolled as research subjects. They were divided into the prosthodontics and orthodontics group (n=49) and the other specialties group (n=65). The baseline maxillary anterior teeth photograph from a 26-year-old female volunteer was set as the control. Eleven images with 4 types of esthetic defects (incisal edge position, gingival margin position, tooth long axis and crown width-to-length ratio) were generated, bringing the total number of study images to 12. After rotation at 0°, 90° and 180°, 36 study images were obtained in total. The images were presented to the subjects via slides, with each image shown for 8s. Two evaluation indicators were adopted:defect detection rate and detection accuracy rate. Subjects were required to determine whether there was a esthetic defect in the image and identify the specific type of defect. A correct detection was defined as accurate judgment of both the existence of the defect and the defect type. The values of the two indicators were calculated, and data were analyzed using the chi-square test with SPSS 27.0 software. Results: The detection rate of aesthetic defects among the 36 images ranged from 23.7% (27/114) to 100.0% (114/114), and the accuracy rate ranged from 5.3% (6/114) to 79.8% (91/114). The difference in detection accuracy among different visual angles was statistically significant: the 0° angle had the highest detection accuracy [52.2% (714/1 368)], followed by the 180° angle [45.1% (617/1 368)], and the 90° angle had the lowest accuracy [26.8% (366/1 368)]. For different tooth positions, the detection accuracy of esthetic defects in central incisors [54.2% (741/1 368)] was significantly higher than that in other positions [34.9% (956/2 736)]. The differences in defect detection accuracy under different visual angles were all statistically significant for incisal edge position, gingival margin position, tooth long axis and crown width-to-length ratio (all P<0.017). There was no statistically significant difference in defect detection accuracy between the prosthodontics and orthodontics group and the other specialties group (P>0.05). Conclusions: Visual angle significantly affects the detection accuracy rate of dental esthetic defects, and the 0° angle is more conducive to the identification of aesthetic defects. Tooth position and defect type also have an impact on the detection accuracy rate. 目的: 探究不同视角对口腔美学区缺陷检出正确率的影响,明确不同牙位、美学缺陷类型及医师专业背景下缺陷检出正确率的差异,为临床口腔美学规范化评价提供参考。 方法: 纳入2025年1至12月参加北京大学口腔医学院·口腔医院门诊部各项继续教育培训的114名口腔执业医师作为受试者,分为修复和正畸专业组(49名)与其他专业组(65名)。以1名26岁女性志愿者上前牙基线像为对照,构建4类(切缘位置、龈缘位置、牙齿长轴、牙冠宽长比)美学缺陷图像共11张,连同基线像总计纳入12张研究图像。每张图像均经0°、90°、180°旋转后获得36张研究图片,通过幻灯片形式展示给受试者,每张图片展示8 s。设置缺陷检出率与检出正确率两项评价指标,受试者需判断图片是否存在美学缺陷及具体缺陷类型,以“缺陷判断+类型识别”均正确为检出正确。计算两项指标数值,数据采用SPSS 27.0软件进行卡方检验分析。 结果: 36张图片的缺陷检出率为23.7%(27/114)~100.0%(114/114),检出正确率为5.3%(6/114)~79.8%(91/114)。不同视角间检出正确率比较差异均有统计学意义(均P<0.001),其中0°视角检出正确率最高[52.2%(714/1 368)],180°视角次之[45.1%(617/1 368)],90°视角最低[26.8%(366/1 368)]。不同牙位之间,中切牙的缺陷检出正确率[54.2%(741/1 368)]均显著高于其余牙位[34.9%(956/2 736)];切缘位置、龈缘位置、牙齿长轴及牙冠宽长比在不同视角下缺陷检出正确率差异均存有统计学意义(P<0.017);正畸和修复专业组与其他专业组缺陷检出正确率差异无统计学意义(P>0.05)。 结论: 视角可显著影响口腔美学区缺陷检出正确率,0°视角更利于对美学缺陷的识别。牙位及缺陷类型对检出正确率存在影响。.

来源:Zhonghua Kou Qiang Yi Xue Za Zhi,查看原文。版权归原作者所有。

引用

  1. Shi XR, Zhang JH, Wu YS, et al. [Analysis of detection accuracy rate of dental esthetic defects under different visual angles]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2026. PMID: 42677435. doi:10.3760/cma.j.cn112144-20260421-00245

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。