文献速递口腔修复与种植口腔颌面外科

增强现实与混合现实导航辅助翼突种植体植入精度的体外研究

Accuracy of Pterygoid Implant Placement With Augmented and Mixed Reality Navigation: An In Vitro Study.
PubMed 文献 · Clin Oral Implants Res · 2026-09-08

本研究利用8例患者锥形束CT数据构建翼突-上颌复合体三维模型,制作32个树脂模型并随机分配至自由手、静态导板、增强现实和混合现实四种植入技术,共植入36枚种植体。结果显示静态导板精度最高,而增强现实和混合现实辅助技术误差较大,尤其在根尖和角度偏差方面。结论认为在体外模型限制下,增强现实和混合现实导航对翼突种植体植入的精度有限。

要点

  • 静态导板辅助翼突种植体植入精度最高,角度偏差3.77°±1.84°。
  • 增强现实和混合现实辅助技术误差较大,混合现实根尖偏差达3.81±1.47 mm。
  • 体外模型条件下,增强现实和混合现实导航精度有限。

核心结论

  • 在体外模型限制下,增强现实和混合现实辅助技术对翼突种植体植入精度有限。

研究设计与样本

  • 体外实验,使用8例患者锥形束CT数据构建三维模型,制作32个树脂模型,随机分配至自由手、静态导板、增强现实和混合现实四组,共植入36枚种植体。

主要发现

  • 静态导板组精度最高:冠状偏差0.86±0.73 mm,根尖偏差1.26±0.60 mm,角度偏差3.77°±1.84°。
  • 自由手、增强现实和混合现实组所有参数偏差均大于静态导板组。
  • 混合现实组误差最大,根尖偏差3.81±1.47 mm,角度偏差12.37°±5.05°。

关键数值与推荐

  • 精度评价指标包括角度偏差和线性偏差(冠状、根尖),通过术前规划与术后三维模型叠加计算。
  • 统计采用单因素重复测量方差分析,显著性水平p<0.05。

临床怎么用

  • 对于翼突种植体植入,静态导板可作为高精度参考方案。
  • 增强现实和混合现实导航在解剖复杂区域的应用需谨慎评估其精度。

局限性

  • 研究为体外模型实验,结果不能直接外推至临床。
  • 样本量较小(8例患者来源,32个模型,36枚种植体)。
  • 仅评估了一种增强现实和混合现实系统,结论可能受技术参数影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the accuracy of augmented reality (AR) and mixed reality (MR)-assisted technologies for pterygoid implant trajectory guidance under anatomically challenging posterior maxillary conditions in the in vitro experimental model. MATERIALS AND METHODS: Cone beam computed tomography datasets from eight patients were used to reconstruct three-dimensional (3D) models of the pterygoid-maxillary complex. Virtual implant placement was performed in planning software, and the corresponding standard tessellation language (STL) files were exported as the preoperative reference. For each patient, four resin models were fabricated and randomly assigned within the patient to the four implant placement techniques (free hand [FH]; static guide [SG]; AR; MR), resulting in 32 models in total. A surgeon placed 36 implants in all models according to group designs. Following implant placement, each model was digitized, and STL datasets were generated. These were superimposed with the preoperative reference STL in 3D analysis software, allowing calculation of angular and linear deviation. One-way repeated measures ANOVA was applied to compare deviations among groups, with significance set at p < 0.05. RESULTS: The SG group demonstrated the highest accuracy (coronal deviation 0.86 ± 0.73 mm; apical deviation 1.26 ± 0.60 mm; angular deviation 3.77° ± 1.84°). In contrast, the FH, AR, and MR groups exhibited greater deviations in all parameters, with the MR group showing the largest errors-particularly in apical deviation (3.81 ± 1.47 mm) and angular deviation (12.37 ± 5.05). CONCLUSIONS: Within the limitations of the in vitro model, the AR and MR-assisted technologies tested in this study demonstrated limited accuracy for pterygoid implant placement.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Ma W, Fu J, Beuer F, et al. Accuracy of Pterygoid Implant Placement With Augmented and Mixed Reality Navigation: An In Vitro Study. Clin Oral Implants Res. 2026. PMID: 42711887. doi:10.1111/clr.70173

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。