新型pH响应抗龋纳米复合水凝胶的研制
本研究开发了一种由甲基丙烯酰化透明质酸、甲基丙烯酰化丝素蛋白和壳聚糖构成,并掺入纳米羟基磷灰石、纳米银和纳米氧化锌的pH响应纳米复合水凝胶(NCH)。该材料在酸性条件下释放钙、银、锌离子显著增加,对变形链球菌具有抗菌活性,并在pH循环后减少牙本质脱矿,显示出作为抗龋生物材料的潜力。
要点
- NCH在pH 4.5下钙、银、锌离子释放显著高于pH 7.5(p < 0.001)。
- NCH对变形链球菌的MIC为211±31 ppm,MBC为500±71 ppm。
- NCH处理牙本质病变深度35±6 μm,低于对照111±19 μm(p < 0.001)。
核心结论
- 该生物相容性NCH具有pH触发离子释放、抗变形链球菌活性及保护牙本质免于脱矿的作用,有望成为抗龋生物材料。
研究设计与样本
- 制备NCH并对其形貌、光学性质、官能团、晶相和化学状态进行表征。
- 通过IC₅₀评估对HGF-1和SHED的细胞毒性。
- 采用ICP-MS测定pH依赖性钙、银、锌离子释放。
- 评估对变形链球菌的MIC和MBC,并用SEM和TEM观察生物膜形态及细菌损伤。
- 通过pH循环后显微CT评估NCH对牙本质脱矿的影响,以水为对照。
主要发现
- 表征确认NCH成功合成。
- IC₅₀值:HGF-1为1440±121 ppm,SHED为1069±78 ppm。
- 180分钟内pH 4.5下的钙、银、锌离子释放显著高于pH 7.5(p < 0.001)。
- MIC为211±31 ppm,MBC为500±71 ppm。
- SEM显示细菌定植减少,TEM显示NCH处理后细菌膜破坏。
临床怎么用
- pH响应NCH在酸性条件下优先释放抗菌和矿化离子,可能支持更靶向、非侵入性的龋病管理策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To develop a pH-responsive nanocomposite hydrogel (NCH) with antibacterial and inhibiting demineralisation properties for anti-caries applications. METHODS: The NCH was formulated from methacrylated hyaluronic acid, methacrylated silk fibroin, and chitosan, and incorporated nano-hydroxyapatite, nano-silver, and nano-zinc oxide. Its morphology, optical properties, functional groups, crystalline phases, and chemical states were characterised by scanning electron microscopy, ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. Cytotoxicity towards human gingival fibroblasts (HGF-1) and stem cells from human exfoliated deciduous teeth (SHED) was assessed by half-maximal inhibitory concentration (IC₅₀). pH-dependent release of calcium, silver, and zinc ions was measured by inductively coupled plasma mass spectrometry. Antibacterial activity against Streptococcus mutans was evaluated using minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC). Biofilm morphology and bacterial damage were examined by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The effect of NCH on dentine demineralisation was assessed by micro-computed tomography after pH cycling, using water as the control. RESULTS: Characterisation confirmed successful synthesis of the NCH. The IC₅₀ values were 1440±121 ppm for HGF-1 and 1069±78 ppm for SHED. Calcium, silver, and zinc ion release over 180 min was significantly greater at pH 4.5 than at pH 7.5 (p < 0.001). The MIC was 211±31 ppm and MBC was 500±71 ppm. SEM showed reduced bacterial colonisation. TEM showed membrane disruption after NCH treatment. Compared with the control, NCH-treated dentine showed a shallower lesion depth (35±6 μm vs 111±19 μm; p < 0.001) and lower mineral loss (0.17± 0.14 gHA/cm³ vs 0.73±0.09 gHA/cm³; p < 0.001). CONCLUSIONS: This biocompatible NCH showed pH-triggered ion release, antibacterial activity against Streptococcus mutans, and mineral-protective effects against dentine demineralisation, indicating promise as an anti-caries biomaterial. CLINICAL SIGNIFICANCE: A pH-responsive NCH that preferentially releases antibacterial and mineralising ions under acidic conditions may support the development of more targeted and non-invasive strategies for caries management.
引用
- Zhang Y, Yin IX, Xu VW, et al. Development of a novel pH-responsive anti-caries nanocomposite hydrogel. J Dent. 2026. PMID: 42435964. doi:10.1016/j.jdent.2026.106897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。