基于深度学习的自动化三维面部软组织标志点检测新方法
本研究提出并评估了一种基于深度学习的三维面部软组织标志点自动检测网络FST-Net,用于检测34个常用标志点和8项测量。297例患者随机分为训练集207例、验证集30例和测试集60例。结果显示全部标志点平均径向误差为1.80±1.81 mm,其中高可重复性标志点误差为1.25±0.90 mm,而依赖主观判断的标志点误差较大为4.39±2.57 mm。
要点
- FST-Net可自动检测34个三维软组织标志点,全部标志点平均径向误差1.80±1.81 mm。
- 高可重复性标志点检测精度较高(1.25±0.90 mm),主观判断标志点误差较大(4.39±2.57 mm)。
- 8项软组织测量中6项平均误差低于2 mm或2°,平均ICC为0.909。
核心结论
- FST-Net在三维软组织标志点自动检测中展现出潜力,对高可重复性标志点效果满意,对主观判断标志点需进一步优化。
研究设计与样本
- 研究纳入297例患者,随机分为训练集207例、验证集30例和测试集60例,采用特征融合与局部坐标回归进行自动标志点检测。
主要发现
- 全部34个标志点的平均径向误差为1.80±1.81 mm。
- 28个高可重复性标志点的平均径向误差为1.25±0.90 mm,6个依赖主观判断的标志点为4.39±2.57 mm。
- 模型在2、2.5、3、4 mm阈值内的成功检测率分别为72.16%、80.69%、85.10%、90.54%。
- 唇部标志点精度最高(1.03±0.69 mm),双侧颊部标志点精度最低(4.39±2.57 mm)。
- 8项软组织测量的手动与自动检测平均ICC为0.909,其中6项平均误差低于2 mm或2°。
临床怎么用
- FST-Net可作为辅助工具快速初步定位三维软组织标志点,减少手动工作量,但侧面部区域仍需临床医生验证。
局限性
- 对依赖主观判断的标志点(Group 2)检测精度不足,需进一步优化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To propose and evaluate a novel deep learning (DL)-based facial soft tissue network (FST-Net) for the automatic detection of 34 commonly used three-dimensional (3D) soft tissue landmarks and eight measurements. METHODS: A total of 297 patient cases were randomly allocated into training (n = 207), validation (n = 30), and testing sets (n = 60) for automated landmark detection through feature fusion and local coordinate regression. The model's performance in terms of landmark localisation and soft tissue measurements was evaluated. RESULTS: The mean radial error (MRE) of all 34 landmarks was 1.80 ± 1.81 mm. For the 28 landmarks with high operator reproducibility (Group 1 landmarks), the MRE was 1.25 ± 0.90 mm, whereas the six landmarks dependent on subjective judgement (Group 2 landmarks) had a larger average error (4.39 ± 2.57 mm). The model achieved successful detection rates (SDRs) within 2, 2.5, 3, and 4 mm of 72.16%, 80.69%, 85.10%, and 90.54%, respectively. By sub-region, lip landmarks had the highest accuracy (1.03 ± 0.69 mm), whereas bilateral cheek landmarks had the lowest (4.39 ± 2.57 mm). The average intra-class correlation coefficient (ICC) values for eight soft tissue measurements were 0.909 between manual and automated detection. Six out of the eight measurements had average errors below 2 mm or 2° CONCLUSION: These findings underscore the potential of deep learning in orthodontics, as exemplified by FST-Net, which offers significant improvements in the accurate and efficient detection of 3D soft tissue landmarks. The method for Group 1 landmarks achieved satisfactory results, whereas for Group 2 landmarks, further optimisation is needed to improve accuracy in future studies. CLINICAL SIGNIFICANCE: FST-Net can automate the detection of 34 commonly used 3D soft tissue landmarks to measure 3D facial characteristics accurately and efficiently, for diagnosis and treatment planning through feature fusion and local coordinate regression. It provides a rapid preliminary landmarking for distinct anatomical features, serving as an auxiliary tool to reduce manual workload, though clinician verification remains mandatory for lateral facial regions.
引用
- Bao H, He Z, Wu J, et al. A new automated 3d facial soft tissue landmarking method via deep learning. J Dent. 2026. PMID: 42103064. doi:10.1016/j.jdent.2026.106742
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。