微CT评估三种水硬性硅酸钙水门汀修复不同根三分之一穿孔性内吸收的体外研究
本研究在3D打印牙复制体上,用micro-CT评估Bio-C Repair、Biodentine和白色MTA-Angelus修复不同根三分之一穿孔性内吸收的充填与封闭性能。结果显示材料性能受缺损位置影响:根尖三分之一WMTA充填和封闭优于BCR和BD(P < .05),根中三分之一无差异(P > .05),根颈三分之一BD挤出多于WMTA(P < .01)。
要点
- 根尖穿孔时WMTA充填和封闭优于BCR和BD(P < .05)。
- 根中三分之一三种材料充填无显著差异(P > .05)。
- 根颈穿孔时BD挤出多于WMTA(P < .01),且BCR在根尖区表面粗糙度更高(P < .05)。
核心结论
- HCSC修复穿孔性内吸收的性能受缺损位置影响,WMTA根尖适应性更可预测,BD在模拟牙周条件下根颈挤出更多。
主要发现
- 根尖PIR中,WMTA充填和封闭优于BCR和BD(P < .05),包括邻接根尖根管的充填更优(P < .001)。
- 根中三分之一无差异(P > .05)。
- 根颈PIR中所有材料充填率高,但BD挤出多于WMTA(P < .01)。
- BCR在根尖PIR中表面粗糙度更高(P < .05)。
临床怎么用
- 根尖穿孔修复可优先考虑WMTA以获得更可预测的适应性和封闭。
- 根颈穿孔使用BD时需注意挤出风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Effective repair of perforating internal resorption (PIR) requires adequate defect filling; however, the influence of defect location on the filling ability of hydraulic calcium silicate cements (HCSCs) remains unclear. This micro-computed tomography (micro-CT) study evaluated Bio-C Repair (BCR), Biodentine (BD), and white MTA-Angelus (WMTA) in three dimensional-printed tooth replicas with PIR defects in different root thirds. The null hypothesis was that material performance would not differ according to defect location. METHODS: A maxillary central incisor was instrumented to size R50 and scanned by micro-CT. PIR defects were digitally created in the apical, middle, and cervical thirds. Ninety replicas were printed and distributed by defect location (n = 30) and HCSC type (n = 10). After obturation, scans quantified cement-filling and extrusion. Surface characteristics were assessed by confocal laser scanning microscopy. Data were analyzed with Welch's analysis of variance (ANOVA) with Games-Howell post hoc and Kruskal-Wallis tests (P < .05). RESULTS: In apical PIRs, WMTA achieved greater filling and sealing than BCR and BD (P < .05), including superior filling of the adjacent apical canal (P < .001). No differences were observed in the middle third (P > .05). In cervical PIRs, all materials showed high filling, although BD exhibited greater extrusion than WMTA (P < .01). BCR presented higher surface roughness in apical PIRs (P < .05). CONCLUSIONS: HCSC performance in PIR repair was influenced by defect location. WMTA demonstrated more predictable apical adaptation, whereas BD showed greater cervical extrusion under simulated periodontal conditions.
引用
- Torres-Carrillo AJS, Mazzi-Chaves JF, Creazzo G, et al. Micro-CT Assessment of Hydraulic Calcium Silicate Cements for Perforating Internal Resorption in 3D-printed Tooth Replicas at Different Root Thirds: An In Vitro Study. J Endod. 2026. PMID: 42128278. doi:10.1016/j.joen.2026.05.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。