文献速递牙体牙髓病

减锥度往复镍钛器械与六种往复系统的机械性能及生物力学对比

Mechanical Performance and Biomechanical Implications of a Reduced-Taper Reciprocating Instrument Compared With 6 Reciprocating Systems.
PubMed 文献 · Int Endod J · 2026-05-22

研究对比了七种往复镍钛器械(含减锥度Reciproc Minima M25)的几何、冶金、机械性能及有限元生物力学表现,共441支新器械。结果显示各器械机械参数差异显著,Reciproc Minima M25循环疲劳抗力最高、柔韧性最好,锥度减小与 blade 体积减小与牙本质应力略低相关。

要点

  • Reciproc Minima M25循环疲劳抗力和柔韧性最优,扭转性能与其他器械相当。
  • Reciproc R25扭转和抗屈曲能力最高,Flash 25/.06vt循环疲劳抗力最低。
  • 预备体积越大牙本质应力越高,保守预备应力集中更低。

核心结论

  • 减锥度Reciproc Minima M25具有高循环疲劳抗力和柔韧性,扭转性能与其他器械相当。
  • 其减锥度和较小 blade 体积与周围牙本质应力略低相关。

研究设计与样本

  • 体外研究,共441支新镍钛器械,来自七种往复系统,每种器械每项机械测试n=10。
  • 采用摄影分析、扫描电镜、高分辨率三维光学扫描评估几何设计,能谱仪和差示扫描量热法评估冶金特性。
  • 机械性能测试包括循环疲劳、扭转、弯曲、屈曲、切割效率和显微硬度,并行有限元分析(基于micro-CT下颌前磨牙模型)。
  • 统计采用Shapiro-Wilk检验和Kruskal-Wallis检验(α=0.05)。

主要发现

  • 所有器械镍钛成分接近等原子比,相变温度不同。
  • Reciproc Minima M25 blade 体积和表面积小于其他系统。
  • 所有机械参数组间差异显著(p < 0.05)。
  • Reciproc Minima M25循环疲劳至断裂时间最长、断裂前旋转角度最大、弯曲载荷最低。
  • Reciproc R25扭转和屈曲抗力最高;Flash 25/.06vt循环疲劳抗力最低;One RECI N25切割效率最高。

临床怎么用

  • 需高循环疲劳抗力和柔韧性的弯曲根管可考虑减锥度Reciproc Minima M25。
  • 需高扭转或抗屈曲能力时Reciproc R25表现更优。
  • 追求切割效率可选One RECI N25,但需注意Flash 25/.06vt循环疲劳抗力较低。
  • 保守预备可能降低牙本质应力集中。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate and compare the geometric characteristics, metallurgical properties, mechanical performance, and biomechanical behaviour of a reduced-taper reciprocating instrument with six commercially available systems. METHODOLOGY: A total of 441 new nickel-titanium (NiTi) instruments from seven reciprocating systems (Excalibur 25/.05, Flash 25/.06vt, One RECI N25, Reciproc R25, Reciproc Blue R25, Reciproc Minima M25, and WaveOne Gold Primary) were analysed. Geometric design was assessed through photographic analysis, scanning electron microscopy, and high-resolution three-dimensional optical scanning to obtain dimensional measurements along the active blade. Metallurgical characteristics were investigated using energy-dispersive X-ray spectroscopy and differential scanning calorimetry. Mechanical performance was evaluated through cyclic fatigue, torsional resistance, bending resistance, buckling resistance, cutting efficiency, and microhardness tests (n = 10 per parameter). In addition, finite element analysis was conducted using a micro-CT-derived mandibular premolar model to assess maximum principal stress distribution and deformation following simulated canal preparations produced by each instrument. Data distribution was analysed using the Shapiro-Wilk test, and intergroup comparisons were performed with the Kruskal-Wallis test (α = 0.05). RESULTS: All instruments presented nearly equiatomic NiTi composition and distinct phase transformation temperatures. Reciproc Minima M25 showed smaller blade volume and surface area compared with the other systems. Significant differences were detected among instruments for all mechanical parameters (p < 0.05). Reciproc Minima M25 demonstrated the longest time to fracture during cyclic fatigue testing and the highest angular rotation before fracture, as well as the lowest bending load, indicating greater flexibility. Reciproc R25 exhibited the highest torsional and buckling resistance. Flash 25/.06vt showed the lowest cyclic fatigue resistance, whereas One RECI N25 presented the highest cutting efficiency. Finite element analysis revealed similar stress patterns across models; however, larger preparation volumes tended to generate higher dentinal stresses, whereas conservative preparations were associated with lower stress concentrations. CONCLUSION: The reduced-taper Reciproc Minima M25 exhibited high cyclic fatigue resistance and flexibility while maintaining a high torsional performance comparable to other instruments. Its reduced taper and smaller blade volume were associated with slightly lower stress values in the surrounding dentine.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Neto F, Martins JNR, Martins RF, et al. Mechanical Performance and Biomechanical Implications of a Reduced-Taper Reciprocating Instrument Compared With 6 Reciprocating Systems. Int Endod J. 2026. PMID: 42171597. doi:10.1111/iej.70184

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。