骨下0.5mm与1.5mm种植体十年随机对照试验
两组在种植失败、并发症、美学及边缘骨吸收方面均无显著差异。
要点
- 骨下0.5mm与1.5mm植入的种植体十年存留率无显著差异。
- 两组并发症发生率、PES评分及患者偏好均无统计学差异。
- 在周围骨量充足时,两种植入深度均可获得良好长期结局。
核心结论
- 在周围至少1mm骨量条件下,骨下0.5mm或1.5mm植入对种植体长期结局无显著影响。
主要发现
- 种植失败0.5mm组7例 vs 1.5mm组3例,差异无统计学意义(p=0.125)。
- 发生并发症患者0.5mm组10例(18.5%) vs 1.5mm组7例(13%),差异无统计学意义(p=0.508)。
- PES评分0.5mm组7.66±3.14 vs 1.5mm组7.46±2.97,差异无统计学意义(p=0.510)。
- 负荷后10年边缘骨丧失0.5mm组平均0.38±0.84mm,1.5mm组0.17±0.45mm,差异无统计学意义(差值-0.21mm;95%CI -0.47至0.04;p=0.097)。
- 患者对植入深度无偏好,各中心间结局无显著差异。
临床怎么用
- 在愈合骨嵴且周围骨量至少1mm时,骨下0.5mm或1.5mm植入均可作为临床选择。
局限性
- 8例患者失访,可能影响结果解释。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate whether placing single dental implants either 0.5 or 1.5 mm subcrestally in healed bone crests confers any clinical benefits. MATERIALS AND METHODS: Sixty partially edentulous patients requiring two single implant-supported crowns were enrolled in a split-mouth design across six centres. Each site was randomly assigned to receive an implant placed either 0.5 or 1.5 mm subcrestally. Patients were followed up to 10 years post-loading. Outcome measures included crown and implant failures, complications, aesthetics assessed using the Pink Esthetic Score (PES), peri-implant marginal bone level changes, and patient preference. RESULTS: Eight patients were lost to follow-up. No statistically significant differences were observed between groups regarding implant failures (7 vs. 3; p = 0.125), patients experiencing complications (10 [18.5%] vs. 7 [13%]; p = 0.508), PES (7.66 ± 3.14 vs. 7.46 ± 2.97, p = 0.510). Ten years post-loading, patients in the 0.5 mm group exhibited an average marginal bone loss of 0.38 ± 0.84 mm, while those in the 1.5 mm group showed 0.17 ± 0.45 mm, a difference that was not statistically significant (difference = -0.21 mm; 95% CI -0.47 to 0.04; p = 0.097). No patient preference for implant placement depth was noted. No significant differences in outcomes were found between centres. CONCLUSIONS: Subcrestal implant placement at either 0.5 or 1.5 mm, when at least 1 mm of surrounding bone is present, seems not to affect the long-term outcomes.
引用
- Esposito M, Visconti RF, Gualini F, et al. Ten-Year Post-Loading Outcomes of Subcrestally Placed Implants With Internal Conical Connections at 0.5 mm Versus 1.5 mm Depth: A Multicentre Within-Person Randomised Controlled Trial. Clin Oral Implants Res. 2026. PMID: 42047281. doi:10.1111/clr.70135
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。