穿黏膜穿出几何形态与种植体周疾病患病率的横断面研究
该横断面研究纳入266例患者共332枚非磨牙单颗种植修复体,评估穿黏膜穿出几何形态与种植体周疾病的关系。结果显示,冠穿出角增大与种植体周黏膜炎和种植体周炎相关,种植体直径增大与种植体周炎患病率升高相关;组织水平种植体和较大修复平台高度与较低骨水平相关。
要点
- 冠穿出角增大与种植体周疾病患病率升高相关。
- 骨水平种植体冠穿出角>30°、组织水平>48°时持续与种植体周疾病相关。
- 种植体直径增大与种植体周炎患病率升高相关。
核心结论
- 较宽的冠穿出角与种植体周疾病相关,较宽的种植体直径与种植体周炎患病率升高相关。
- 组织水平种植体设计和较大的修复平台高度与较低的嵴骨水平相关。
研究设计与样本
- 横断面研究,回顾性识别非磨牙单颗种植修复患者,进行临床和影像学检查,采用多变量回归分析。
- 共评估266例患者(60±17岁)的332枚种植体(166枚骨水平/166枚组织水平),种植体植入后平均11.2±1.5年。
主要发现
- 种植体周黏膜炎显著受冠穿出角(Level 2)影响(OR=1.03,p=0.01)。
- 种植体周炎显著受种植体直径影响(OR=3.82,p<0.0001)。
- 骨水平种植体冠穿出角>30°、组织水平种植体>48°时持续与种植体周疾病相关。
- 平均嵴骨水平为0.54±1.34 mm,组织水平种植体(-0.24 mm;p=0.036)、女性(-0.27 mm,p=0.029)和较大平台高度(-0.175 mm/mm,p=0.01)者嵴骨水平更低。
- 13.4%的种植体检测到种植体周鞘状结构,与种植体相关特征无关联。
关键数值与推荐
- 冠穿出角(Level 2)与种植体周黏膜炎相关:OR=1.03,p=0.01。
- 种植体直径与种植体周炎相关:OR=3.82,p<0.0001。
- 骨水平种植体冠穿出角>30°、组织水平种植体>48°持续与种植体周疾病相关。
- 平均嵴骨水平0.54±1.34 mm;组织水平种植体-0.24 mm(p=0.036);女性-0.27 mm(p=0.029);平台高度每增加1 mm嵴骨水平降低0.175 mm(p=0.01)。
- 种植体周鞘状结构检出率13.4%。
临床怎么用
- 临床设计单颗种植修复体时,应关注冠穿出角,避免过大的穿出角以降低种植体周疾病风险。
- 选择种植体直径时需权衡种植体周炎风险,较宽直径可能与种植体周炎患病率升高相关。
- 组织水平种植体和较大修复平台高度可能与较低嵴骨水平相关,可作为临床决策参考。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This cross-sectional study primarily aimed at investigating the association between the transmucosal emergence geometry and the prevalence of peri-implant diseases in bone- and tissue-level implants (BL/TL). As secondary objectives, the association of other implant-, prosthesis-, and patient-related variables with crestal bone levels (CBL) and additional radiographic findings was explored. MATERIAL AND METHODS: Patients with non-molar single tooth implant-supported prostheses were retrospectively identified for inclusion. Clinical and radiographic examinations were performed cross-sectionally to assess peri-implant diseases (peri-implant mucositis, peri-implantitis), emergence geometry at the transmucosal region (profile type, emergence angles at two levels, and prosthetic platform height), and peri-implant radiographic variables, including CBL. Data were analyzed using multivariate regression. RESULTS: A total of 332 implants (166 BL/166 TL) in 266 patients (60 ± 17 years) were evaluated at a mean of 11.2 ± 1.5 years after implant placement. Peri-implant mucositis was significantly influenced by the crown emergence angle (Level 2; OR = 1.03, p = 0.01) and peri-implantitis by implant diameter (OR = 3.82, p < 0.0001). Crown emergence angles > 30° in BL implants and > 48° in TL implants were consistently associated with peri-implant diseases. Mean CBL was 0.54 ± 1.34 mm, with lower values in TL (-0.24 mm; p = 0.036), females (-0.27 mm, p = 0.029), and implants with greater platform height (-0.175 mm/mm, p = 0.01). Peri-implant sheathing was detected in 13.4% of implants, showing no association with implant-related characteristics. CONCLUSIONS: Wider crown emergence angles were associated with peri-implant diseases, whereas wider implant diameters were associated with increased peri-implantitis prevalence. TL implant design and greater platform height were associated with reduced CBL.
引用
- Raabe C, Fonseca M, Chappuis V, et al. Association of Transmucosal Emergence Geometry and Peri-Implant Diseases Prevalence Around Bone- and Tissue-Level Implants: A Cross-Sectional Study. Clin Oral Implants Res. 2026. PMID: 41966820. doi:10.1111/clr.70131
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。