文献速递口腔颌面外科

动态导航辅助与传统下颌第三磨牙冠切术精度对比的随机对照试验

The relative accuracy of dynamic navigation-guided and conventional coronectomy for mandibular third molars: A randomized controlled trial.
PubMed 文献 · J Dent · 2026-03-10

单盲随机对照试验纳入110例下颌第三磨牙冠切术患者,最终分析107例117颗牙。动态导航组在截骨平面均方根偏差(整体1.02±0.50 mm)显著低于徒手组(1.44±0.90 mm,P<0.05),但手术时间显著延长(28 min vs. 14 min,P<0.05)。

要点

  • 动态导航辅助冠切术截骨精度达毫米级,优于传统徒手技术。
  • 导航组整体、近中及远中均方根偏差均显著低于徒手组(P<0.05)。
  • 导航组手术时间显著长于徒手组(28 min vs. 14 min,P<0.05)。

核心结论

  • 动态导航显著提高下颌第三磨牙冠切术的截骨精度,达到毫米级精度并超越徒手技术。

研究设计与样本

  • 单盲随机对照试验,纳入110例下颌第三磨牙冠切术患者,退出3例后最终分析107例患者(117颗牙)。
  • 牙随机分配至动态导航辅助组(52例患者,57颗牙)或徒手组(55例患者,60颗牙)。

主要发现

  • 动态导航组整体均方根偏差1.02±0.50 mm,近中1.06±0.58 mm,远中0.92±0.54 mm,均显著低于徒手组(整体1.44±0.90 mm,近中1.46±1.07 mm,远中1.48±1.25 mm,P<0.05)。
  • 动态导航在最大正偏差、平均正偏差、均方根曲率及最小曲率值方面也表现出一致优势。
  • 动态导航组手术时间显著长于徒手组(28 min vs. 14 min,P<0.05)。

关键数值与推荐

  • 主要结局为术后截骨平面与术前虚拟计划的均方根偏差,评估整体及近中、远中分区。
  • 次要结局包括各区域最大和平均正负偏差、曲率参数(均方根、最大值、最小值)及手术总时长和有效操作时间。

临床怎么用

  • 动态导航辅助冠切术可提高截骨精度,适用于复杂下颌第三磨牙手术以提升安全性和精确性。
  • 临床需权衡导航带来的精度优势与手术时间延长(28 min vs. 14 min)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to evaluate and compare the surgical precision of coronectomy for mandibular third molars (M3Ms) performed with the aid of a dynamic navigation system (DNS) versus the conventional freehand technique. METHODS: A single-blind randomized controlled trial was conducted in 110 patients undergoing M3M coronectomy. After withdrawal of three patients, 107 patients (teeth, N = 117) were included in the final analysis. Teeth were randomly allocated to the DNS-assisted group (patients, n = 52; teeth, N = 57) or the freehand group (patients, n = 55; teeth, N = 60). The primary outcome measure was the root mean square (RMS) deviation between the achieved osteotomy plane and the preoperative virtual plan, assessed for the entire resection surface as well as the mesial and distal subregions. Secondary outcomes included: (i) maximum and mean positive and negative deviations in all regions; (ii) curvature parameters (RMS, maximum, and minimum) for the complete osteotomy plane and its subregions; and (iii) total procedure duration and active operative time. Postoperative cone-beam computed tomography (CBCT) scans were processed with Geomagic software for three-dimensional deviation analysis. RESULTS: The DNS-assisted group showed significantly reduced RMS deviations (overall: 1.02 ± 0.50 mm; mesial: 1.06 ± 0.58 mm; distal: 0.92 ± 0.54 mm) compared with the freehand group (overall: 1.44 ± 0.90 mm; mesial: 1.46 ± 1.07 mm; distal: 1.48 ± 1.25 mm; P < 0.05). Consistent advantages of DNS were also observed in maximum and mean positive deviations, RMS curvature, and minimum curvature values. However, operative duration was significantly longer with DNS than with the freehand method (28 min vs. 14 min, P < 0.05). CONCLUSIONS: Dynamic navigation significantly improves the accuracy of M3M coronectomy, achieving millimeter-level precision that surpasses that of the freehand technique. CLINICAL SIGNIFICANCE: These findings highlight the value of a fully digital workflow from preoperative planning through postoperative validation in DNS-guided coronectomy, underscoring its potential to improve safety and precision in complex M3M surgeries.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Wu BZ, Lin JN, Liu QX, et al. The relative accuracy of dynamic navigation-guided and conventional coronectomy for mandibular third molars: A randomized controlled trial. J Dent. 2026. PMID: 41812978. doi:10.1016/j.jdent.2026.106621

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。