院内制作隐形矫治器的三维精度:计划与实现牙位的回顾性比较
结果显示计划与实现牙位三维一致性高,各项线性与角度变量均无统计学显著差异(p>0.05),偏差均低于预设阈值,切缘位置、尖牙间宽度与磨牙间宽度差异极小。
要点
- 院内隐形矫治虚拟计划与实现牙位三维一致性高,无临床意义差异
- 各项线性与角度变量差异均无统计学意义(p>0.05),偏差低于0.5 mm与2°阈值
- 三维配准可作为客观的开源工具审计矫治结果并优化数字计划
核心结论
- 院内隐形矫治工作流的虚拟计划与实现牙位三维精度高,无临床意义差异,支持其临床可预测性。
研究设计与样本
- T1与T2 STL模型用基于标志点的三维配准方案配准,并用Slicer CMF 4.11量化线性与角度差异。
- 统计采用5%显著性水平,含15天间隔的检查者自身可靠性评估与Wilcoxon符号秩检验。
- 临床相关阈值定义为线性位移>0.5 mm、角度偏差>2°。
主要发现
- 所有线性与角度变量均无统计学显著差异(p>0.05)。
- 观察到的偏差均低于预设临床相关阈值。
- 切缘位置、尖牙间宽度与磨牙间宽度在T1与T2间差异极小。
关键数值与推荐
- 临床相关阈值:线性位移>0.5 mm、角度偏差>2°。
- 线性与角度变量比较均p>0.05。
- 检查者自身可靠性在15天间隔后评估。
临床怎么用
- 院内隐形矫治系统让临床医生完全掌控数字计划与制作,可预测性支持可靠治疗。
- 可减少再修整需求并提升临床效率。
- 三维配准可作为客观、开放获取的工具,用于审计疗效并优化日常数字计划策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the three-dimensional clinical predictability of an in-office aligner workflow by comparing digitally planned virtual setups (T1) with post-treatment dental models (T2) using a reproducible open-source protocol. METHODS: Sixty-eight digital dental models (maxillary and mandibular arches) from adult patients treated with in-office aligners were retrospectively analyzed. T1 and T2 STL models were superimposed using a landmark-based three-dimensional protocol, and linear and angular discrepancies were quantified using freely available Slicer CMF software (version 4.11). Statistical analyses were conducted at a 5% significance level, including intraexaminer reliability assessment after a 15-day interval and Wilcoxon signed-rank test for paired comparisons. Clinically relevant thresholds were defined as linear displacements >0.5 mm and angular deviations >2° RESULTS: Planned and achieved tooth positions showed high three-dimensional agreement. No statistically significant differences were detected for any linear or angular variables (p > 0.05), and all observed deviations remained below predefined clinical relevance thresholds. Incisal edge positions, intercanine widths, and intermolar widths exhibited minimal discrepancies between T1 and T2. CONCLUSIONS: Virtual setups for in-office aligner therapy demonstrated high three-dimensional accuracy, with no clinically meaningful differences between planned and achieved tooth positions. These findings support the clinical predictability of digitally planned, in-office aligners. CLINICAL RELEVANCE: In-office aligner systems provide clinicians with full control over digital planning and fabrication. Their demonstrated predictability supports reliable treatment, reduces the need for refinements, and improves clinical efficiency. Moreover, three-dimensional superimposition may serve as an objective, open-access tool for auditing treatment outcomes and refining digital planning strategies in daily clinical practice.
引用
- de Souza CR, Barreto BCT, Barreto LSDC, et al. Three-dimensional accuracy of in-office aligner therapy: a retrospective comparison between planned and achieved tooth positions. J Dent. 2026. PMID: 41864463. doi:10.1016/j.jdent.2026.106636
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。