文献速递口腔修复与种植

口内扫描与CBCT配准在机器人辅助种植手术中的精度比较:随机对照试验

Comparative Accuracy of Intraoral Scanning and CBCT Registration in Robotic Computer-Assisted Implant Surgery for Partially Edentulous Patients: A Randomised Controlled Trial.
PubMed 文献 · J Clin Periodontol · 2026-03-29

结果显示两组种植体平台偏差、根尖偏差及角度偏差均无统计学显著差异(p > 0.05),两组种植体存活率和患者满意度均为100%。结论认为IOS配准不劣于CBCT配准,可作为无辐射的配准替代方案。

要点

  • IOS配准与CBCT配准在r-CAIS中的种植体位置精度无显著差异。
  • IOS组平台偏差0.89(0.65)mm,CBCT组0.88(0.42)mm。
  • IOS可作为无辐射配准替代方案用于有足够稳定余留牙的部分缺牙患者。

核心结论

  • 在r-CAIS中,术前IOS配准对种植体精度的效果不劣于CBCT配准,支持其作为无辐射配准替代方案用于有足够数量稳定余留牙的部分缺牙患者。

主要发现

  • IOS组全局平台偏差、全局根尖偏差和角度偏差分别为均值±标准差0.89(0.65)mm、0.95(0.77)mm和1.91(1.98)°。
  • CBCT组对应值分别为0.88(0.42)mm、0.98(0.46)mm和1.84(1.46)°。
  • 无论颌位或缺牙间隙长度如何,IOS组与CBCT组间均无统计学显著差异(p > 0.05)。
  • 两组种植体存活率和患者满意度均为100%。

临床怎么用

  • 对于有足够数量稳定余留牙的部分缺牙患者,可考虑采用IOS配准替代CBCT配准进行r-CAIS,以减少辐射暴露。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the impact of intraoral scanning (IOS) and cone-beam computed tomography (CBCT) registration on implant positional accuracy in robotic computer-assisted implant surgery (r-CAIS). MATERIALS AND METHODS: Patients requiring implant placement in the anterior or premolar regions were enrolled and randomly allocated to either a CBCT group or an IOS group at a 1:1 ratio. Implant positional accuracy was assessed by comparing planned versus actual implant positions using global platform deviation, global apex deviation and angular deviation. Subgroup analyses were performed based on jaw position and span length. The implant survival rate and patient satisfaction were recorded at prosthesis delivery. Statistical analysis was performed using linear mixed-effects modelling. RESULTS: Thirty-two patients were included (16 patients with 25 implants in each group). In the IOS group, the global platform deviation, global apex deviation and angular deviation were reported as mean ± standard deviation (SD): 0.89 (0.65) mm, 0.95 (0.77) mm and 1.91 (1.98)°, respectively. In the CBCT group, the corresponding values were 0.88 (0.42) mm, 0.98 (0.46) mm and 1.84 (1.46)°. No statistically significant differences were found between IOS and CBCT groups (p > 0.05) regardless of jaw position or edentulous span. The implant survival rate and patient satisfaction were 100% in both groups. CONCLUSIONS: Preoperative registration using IOS is non-inferior to CBCT-based registration in implant accuracy for r-CAIS, supporting its application as a radiation-free alternative for registration in partially edentulous patients with sufficient number of stable residual teeth. TRIAL REGISTRATION: ChiCTR2400093045.

来源:J Clin Periodontol,查看原文。版权归原作者所有。

引用

  1. Wang Y, Chen J, Zhao Y, et al. Comparative Accuracy of Intraoral Scanning and CBCT Registration in Robotic Computer-Assisted Implant Surgery for Partially Edentulous Patients: A Randomised Controlled Trial. J Clin Periodontol. 2026. PMID: 41905961. doi:10.1111/jcpe.70120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。