文献速递口腔修复与种植口腔颌面外科

真空成型定位导板辅助个性化钛网在前上颌骨缺损中的放置误差与骨再生

Placement Error and Bone Regeneration of Customized Titanium Mesh With Vacuum-Formed Placing Template for Anterior Maxillary Bone Defects: A Retrospective Case Series Study.
PubMed 文献 · Clin Oral Implants Res · 2026-03-13

回顾性病例系列纳入10例患者(23枚种植体),评估真空成型定位导板引导3D打印个性化钛网在前上颌骨缺损GBR中的放置误差、骨再生及钛网暴露。钛网颊侧位移0.57±0.65 mm,根方位移0.58±0.57 mm,轮廓偏差从0.70±0.20 mm降至0.37±0.12 mm,植骨体积准确度达91.1%±7.6%,非感染性钛网暴露发生率为26%的种植位点。

要点

  • 真空成型导板辅助3D打印钛网放置可行,轮廓偏差术后5-8个月降至0.37±0.12 mm
  • 植骨体积准确度达91.1%±7.6%,但非感染性钛网暴露见于26%种植位点
  • 暴露组垂直骨吸收1.69±1.56 mm,非暴露组仅0.14±0.63 mm

核心结论

  • 真空成型定位导板辅助3D打印个性化钛网放置是前上颌骨GBR的可行方法,但存在一定放置误差和钛网暴露风险。

研究设计与样本

  • 回顾性病例系列研究,纳入10例患者共23枚种植体,骨缺损分类为Terheyden 2/4或3/4。
  • 采集术前(T0)、术后即刻(T2)及术后5-8个月(T3)CBCT数据,与术前设计模型(T1)共同配准至统一坐标系。

主要发现

  • 钛网从T1到T2颊侧位移0.57±0.65 mm,从T2到T3根方位移0.58±0.57 mm。
  • 钛网轮廓偏差T1至T2为0.70±0.20 mm,T2至T3降至0.37±0.12 mm。
  • T2相比T1植骨体积准确度达91.1%±7.6%。
  • 非感染性钛网暴露发生于26%的种植位点。
  • T2至T3暴露组垂直骨吸收1.69±1.56 mm,非暴露组0.14±0.63 mm。

临床怎么用

  • 对于前上颌骨缺损需GBR的病例,可考虑使用真空成型定位导板辅助3D打印个性化钛网放置。
  • 术后应密切监测钛网暴露,尤其注意暴露可能伴随的垂直骨吸收增加。

局限性

  • 本文为回顾性病例系列研究,样本量有限(10例患者,23枚种植体),结论受研究设计限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate placement error, bone regeneration, and mesh exposure of three-dimensionally printed customized titanium mesh (3DPC Ti-mesh) guided by a vacuum-formed placing template in guided bone regeneration (GBR) for anterior maxillary defects. MATERIAL AND METHODS: 10 patients (23 implants) with Terheyden 2/4 or 3/4 defects were included. CBCT data of pre-operation (T0), immediate post-operation (T2), and 5-8 months post-operation (T3) were reconstructed. These three models and preoperative design (T1) model were co-registered to a common coordinate system. Mesh displacement and contour discrepancy were measured. Bone regeneration was evaluated in terms of bone volume and implant-related bone height and width. Classification, time, and rate of mesh exposures were recorded. RESULTS: Ti-mesh exhibited 0.57 ± 0.65 mm buccal displacement from T1 to T2 and 0.58 ± 0.57 mm apical displacement from T2 to T3. Mesh contour discrepancy was 0.70 ± 0.20 mm between T1 and T2 and decreased to 0.37 ± 0.12 mm between T2 and T3. Comparing T2 to T1, graft volume accuracy reached 91.1% ± 7.6%. Non-infected mesh exposure occurred in 26% implant sites. From T2 to T3, vertical bone resorption of 1.69 ± 1.56 mm and 0.14 ± 0.63 mm were recorded in exposed and non-exposed groups, respectively. CONCLUSIONS: To our knowledge, this is the first study to validate the use of a vacuum-formed template for positioning 3DPC Ti-mesh. Within the study limitations, this technique is a feasible approach for placing customized mesh in anterior maxillary GBR.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Zhang S, Zhou M, Zhao Y, et al. Placement Error and Bone Regeneration of Customized Titanium Mesh With Vacuum-Formed Placing Template for Anterior Maxillary Bone Defects: A Retrospective Case Series Study. Clin Oral Implants Res. 2026. PMID: 41826268. doi:10.1111/clr.70115

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。