自主式口腔种植机器人在即刻与延期种植中的精度比较

[Accuracy comparison of an autonomous dental implant robotic system in immediate and delayed implant placement].
PubMed 文献 · Zhonghua Kou Qiang Yi Xue Za Zhi · 2026-01-01

回顾性研究纳入44例患者共60枚种植体,比较自主式口腔种植机器人即刻与延期种植的三维位置偏差,发现两组植入点、根尖点及角度偏差均无统计学差异,机器人系统在不同种植时机下均能获得良好的三维位置精度。

要点

  • 自主式种植机器人在即刻与延期种植中均能获得良好的三维位置精度。
  • 即刻种植组与延期种植组的三维位置偏差无统计学差异。
  • 机器人系统可弥补拔牙窝复杂解剖及术者操作差异的影响。

核心结论

  • 自主式口腔种植机器人用于即刻和延期种植均能获得良好的三维位置和角度精度。

研究设计与样本

  • 回顾性队列研究纳入2022年4月至2025年8月青岛大学附属医院口腔种植科44例缺牙患者,男25例、女19例,年龄22~45岁,共植入60枚种植体。

主要发现

  • 即刻种植组植入点偏差、根尖点偏差及角度偏差分别为0.325(0.190)、0.375(0.380)mm及0.645°(0.170°)。
  • 延期种植组植入点偏差、根尖点偏差及角度偏差分别为0.365(0.200)、0.350(0.100)mm及0.665°(0.160°)。
  • 两组各精度指标差异均无统计学意义(均P>0.05)。

临床怎么用

  • 临床中可考虑使用自主式口腔种植机器人进行即刻或延期种植,以获得良好的三维位置精度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To compare the three-dimensional positional deviations of immediate and delayed implant placement by using autonomous dental implant robotic system, and to evaluate the clinical applicability and operational stability of the robotic system under different conditions. Methods: This retrospective study included 44 patients (25 males and 19 females, aged 22-45 years) who underwent autonomous oral implant robotic surgery at the Department of Oral Implantology, The Affiliated Hospital of Qingdao University, between April 2022 and August 2025. A total of 60 implants were placed, with 20 patients (30 implants) in the immediate implant group and 24 patients (30 implants) in the delayed implant group. Preoperative cone-beam CT and intraoral scans were performed on all patients, and preoperative three-dimensional implant planning was conducted based on the imaging data. The autonomous oral implant robotic system autonomously completed osteotomy and implant placement according to the preoperative plan. Postoperatively, cone-beam CT was taken and superimposed with the preoperative plan, and the deviations in the implant site, apex point, and angular deviation were calculated as precision evaluation indicators. The normality of the data was assessed using the Shapiro-Wilk test. Differences between the two groups were evaluated using the Student's t-test, Welch's t-test, or Mann-Whitney U test. Results: The median (interquartile range, IQR) of the implant site deviation, apex point deviation, and angular deviation in the immediate implant group were 0.325 (0.190), 0.375 (0.380) mm, and 0.645° (0.170°), respectively. In the delayed implant group, the corresponding values were 0.365 (0.200), 0.350 (0.100) mm, and 0.665° (0.160°). Statistical analysis showed no significant differences in the three-dimensional positional accuracy between the two groups (all P>0.05). Conclusions: The autonomous dental implant robotic system provides excellent three-dimensional positioning accuracy in both immediate and delayed implant placements, effectively compensating for complex extraction socket anatomy and operator variability. 目的: 比较自主式口腔种植机器人系统即刻种植与延期种植的三维位置偏差,以评估其在不同种植时机下的临床适用性与操作稳定性。 方法: 本回顾性队列研究纳入2022年4月至2025年8月于青岛大学附属医院口腔种植科行自主式口腔种植机器人手术的44例缺牙患者(25例男性,19例女性,年龄22~45岁),共植入60枚种植体,其中即刻种植组20例(30枚),延期种植组24例(30枚)。所有患者术前均接受锥形束CT扫描及口内扫描,术前结合影像数据进行种植方案三维设计。术中使用自主式口腔种植机器人根据术前规划自主完成窝洞预备与种植体植入,术后通过锥形束CT与术前规划配准,计算植入点偏差、根尖点偏差及角度偏差作为精度评价指标。采用Shapiro-Wilk检验分析数据正态性,并通过Student′s t检验、或Mann-Whitney U检验评估两组差异。 结果: 即刻种植组植入点偏差、根尖点偏差及角度偏差分别为0.325(0.190)、0.375(0.380)mm及0.645°(0.170°);延期种植组植入点偏差、根尖点偏差及角度偏差分别为0.365(0.200)、0.350(0.100)mm及0.665°(0.160)°,两组各指标差异均无统计学意义(均P>0.05)。 结论: 使用自主式口腔种植机器人进行即刻和延期种植,种植体均能获得良好的三维位置和角度精度,可有效弥补拔牙窝复杂解剖环境及术者操作差异带来的影响。.

来源:Zhonghua Kou Qiang Yi Xue Za Zhi,查看原文。版权归原作者所有。

引用

  1. Qi ZQ, Li XH, Wang XY, et al. [Accuracy comparison of an autonomous dental implant robotic system in immediate and delayed implant placement]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2026. PMID: 41786529. doi:10.3760/cma.j.cn112144-20251113-00448

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。