可注射纳米纤维凝胶在兔模型中增强骨整合
研究开发了一种可注射自组装肽纳米纤维界面,在兔模型中比较其与SLA表面对钛种植体骨整合的影响。5周时纳米纤维组BIC达58.7%、BV/TV达51.8%、反向扭矩达53.2 N·cm,均显著优于SLA组。该界面可克服传统涂层局限并预防钻孔微损伤。
要点
- 可注射纳米纤维界面在兔模型中5周时显著提高BIC、BV/TV和反向扭矩。
- 该界面设计为骨诱导、粘附和抗菌,可填充种植体周围微裂纹。
- 适用于骨质量欠佳或种植失败风险较高的患者。
核心结论
- 可注射自组装肽纳米纤维界面在兔模型中显著增强骨-种植体整合和生物力学稳定性。
研究设计与样本
- 兔模型研究,定制钛种植体分别应用纳米纤维界面或SLA表面,3周和5周评估骨整合。
主要发现
- 5周时纳米纤维组BIC为58.7%,SLA组为50.5%(P < 0.001)。
- 5周时纳米纤维组BV/TV为51.8%,SLA组为42.6%(P < 0.001)。
- 5周时纳米纤维组反向扭矩为53.2 N·cm,SLA组为41.8 N·cm(P < 0.01)。
关键数值与推荐
- 5周BIC:纳米纤维界面58.7% vs SLA 50.5%(P < 0.001)。
- 5周BV/TV:纳米纤维界面51.8% vs SLA 42.6%(P < 0.001)。
- 5周反向扭矩:纳米纤维界面53.2 N·cm vs SLA 41.8 N·cm(P < 0.01)。
临床怎么用
- 可注射纳米纤维界面可在种植体植入前应用,作为可流动的骨切开衬里增强骨整合。
- 对骨质量欠佳或种植失败风险较高的患者,该策略有望改善长期临床结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
High insertion torque can cause conventional bioactive implant coatings to delaminate, generating debris and compromising osseointegration. We developed and evaluated an injectable, self-assembling peptide nanofiber interface designed to be applied in the osteotomy site to enhance biomechanical stability and accelerate bone formation. A multifunctional, injectable gel was formed from self-assembling peptide amphiphiles designed to be osteoinductive, adhesive, and antimicrobial. In a rabbit model, custom titanium implants were placed with either the nanofiber interface or a standard sand-blasted, large-grit, acid-etched (SLA) surface. Osseointegration was evaluated at 3 and 5 wk using micro-computed tomography (micro-CT) for bone-to-implant contact (BIC) and bone volume/total volume (BV/TV), as well as biomechanical reverse torque testing. At 5 wk, implants with the nanofiber interface demonstrated significantly superior osseointegration. BIC reached 58.7% compared to 50.5% for SLA-treated implants (P < 0.001). BV/TV was also significantly higher at 51.8% versus 42.6% for the SLA group (P < 0.001). Crucially, biomechanical stability was markedly improved, with the nanofiber group withstanding a reverse torque of 53.2 N·cm, significantly higher than the 41.8 N·cm for the SLA group (P < 0.01). This injectable nanofiber interface successfully overcomes the limitations of traditional coatings by enhancing bone-implant integration and providing superior biomechanical stability. Uniquely, it is designed to prevent or repair drilling-induced microdamage, occupy peri-implant microcracks with a structural nanoscaffold, and act as a flowable, conformal osteotomy liner when applied prior to implant insertion. This practical approach represents a promising strategy to improve long-term clinical outcomes, particularly in patients with compromised bone quality or a higher risk of implant failure.
引用
- Yaylacı S, Eberliköse H, Yüregir Y, et al. Injectable Nanofiber Gel Enhances Osseointegration in a Rabbit Model. J Dent Res. 2026. PMID: 41902600. doi:10.1177/00220345261425649
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。