机器人辅助种植手术种植体植入精度的Meta分析
结果显示平台偏差0.75 mm(95%CI 0.68;0.83)、根尖偏差0.79 mm(95%CI 0.71;0.87)、角度偏差1.88°(95%CI 1.55;2.20),r-CAIS精度显著优于非引导种植,且根尖和角度偏差小于静态CAIS,角度偏差小于动态CAIS,上颌与下颌无差异。
要点
- r-CAIS平台偏差0.75 mm、根尖偏差0.79 mm、角度偏差1.88°
- r-CAIS精度显著优于非引导种植
- r-CAIS根尖和角度偏差小于静态CAIS,角度偏差小于动态CAIS
核心结论
- 在现有研究局限下,r-CAIS可实现高水平的种植体植入精度。
- 未来需更多与其他植入方法的对比临床试验以增强证据。
研究设计与样本
- 在Scopus、MEDLINE/PubMed和Cochrane Library检索前瞻性临床研究。
- 纳入报告平台、根尖和角度偏差的精度的研究。
主要发现
- r-CAIS总体平台偏差0.75 mm(95%CI 0.68;0.83)。
- r-CAIS总体根尖偏差0.79 mm(95%CI 0.71;0.87)。
- r-CAIS总体角度偏差1.88°(95%CI 1.55;2.20)。
- r-CAIS偏差显著小于非引导种植。
- r-CAIS根尖和角度偏差小于静态CAIS,角度偏差小于动态CAIS;上颌与下颌精度无差异。
临床怎么用
- r-CAIS可用于实现高精度种植体植入。
- 临床选择时需注意现有对比研究数量有限。
局限性
- 仅少数 comparative 研究。
- 需未来更多对比临床试验以提供更稳健结论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to assess the trueness of dental implant placement with robotic Computer-Assisted Implant Surgery (r-CAIS), compare it with non-guided and other CAIS approaches, and investigate potential differences between sites in the maxilla and mandible. MATERIALS AND METHODS: A literature search was carried out in Scopus, MEDLINE/PubMed, and Cochrane Library to find prospective clinical studies where r-CAIS was used either as the sole procedure or compared with other CAIS approaches. Studies reporting trueness measured by means of deviation on platform, apex, and angle were included. RESULTS: Nineteen studies were eligible. The overall implant deviation using r-CAIS was 0.75 mm (95% Confidence interval [CI] = 0.68; 0.83), 0.79 mm (95% CI = 0.71; 0.87), and 1.88° (95% CI = 1.55; 2.20), in platform, apex, and angle, respectively. r-CAIS showed significantly less deviation compared to non-guided implant placement. Moreover, r-CAIS demonstrated less apex and angle deviation than static CAIS, and less angle deviation than dynamic CAIS. No difference in the trueness between the maxilla and the mandible was noted. CONCLUSIONS: Although several clinical trials on r-CAIS are now available, only a few comparative studies have been performed. Within these limitations, r-CAIS can achieve a high level of trueness in implant placement. Future comparative clinical trials with other implant placement methods are needed to augment the available evidence and provide more robust conclusions.
引用
- Shuborna NS, Jiaranuchart S, Chow J, et al. Trueness of Dental Implant Placement With Robotic Computer-Assisted Implant Surgery: A Meta-Analysis of Clinical Studies. Clin Oral Implants Res. 2026. PMID: 41681039. doi:10.1111/clr.70102
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。