文献速递牙体牙髓病

聚丙烯针与多种辅助冲洗技术在弯曲根管清洁中的疗效与溢出风险比较

Comparative Efficacy and Extrusion Risk of Polypropylene Needle versus Various Supplemental Irrigations in Cleaning Simulated Curved Root Canals.
PubMed 文献 · J Endod · 2026-02-19

这项体外研究在20°和40°弯曲的模拟根管中比较了聚丙烯针与多种辅助冲洗技术的清洁效果和冲洗液溢出。结果显示,在严重弯曲根管中聚丙烯针的主根管残留水凝胶少于不锈钢针,但所有辅助技术均优于聚丙烯针,其中MDA-M清洁最佳但溢出最高。

要点

  • 聚丙烯针在40°弯曲根管中主根管清洁优于不锈钢针。
  • 所有辅助冲洗技术在两种弯曲度下均优于聚丙烯针。
  • MDA-M主根管和副根管清洁最佳,但冲洗液溢出最高。

核心结论

  • 在严重弯曲根管中,聚丙烯针相比不锈钢针可改善根尖区清洁。
  • 辅助激活技术在两种弯曲度下整体清创效果更优,但增加了冲洗液溢出风险。

研究设计与样本

  • 体外研究,使用20°(中度)和40°(重度)弯曲的模拟根管,预备至25/0.07并填充模拟生物膜的水凝胶。
  • 比较六种冲洗技术(每组n=9):不锈钢针常规冲洗、聚丙烯针常规冲洗、不锈钢针辅以0.04锥度标准锥手动动态 agitation(MDA-S)、匹配锥手动动态 agitation(MDA-M)、EDDY声波激活、XP-endo Finisher机械激活。
  • 评估主根管残留水凝胶、副根管水凝胶清除及根尖孔冲洗液溢出,采用双因素方差分析和Bonferroni事后检验(P < .05)。

主要发现

  • 在严重弯曲根管中,聚丙烯针的主根管残留水凝胶显著少于不锈钢针(P < .05)。
  • 在两种弯曲度下,所有辅助技术均显著优于聚丙烯针(P < .05)。
  • MDA-M在主根管和副根管中水凝胶清除最多(P < .05),但冲洗液溢出最高(P < .05)。

临床怎么用

  • 对于严重弯曲根管,可考虑使用聚丙烯针以改善根尖区清洁。
  • 若追求更强清创效果,辅助激活技术优于常规针冲洗,但需注意冲洗液溢出风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This in vitro study compared the cleaning efficacy and irrigant extrusion of polypropylene needles and various supplemental irrigation techniques in curved root canals. METHODS: Simulated canals with 20° (moderate) and 40° (severe) curvatures were prepared to size 25/0.07 and filled with biofilm-mimicking hydrogel. Six irrigation techniques were tested (n = 9 per group): conventional irrigation with stainless steel needles, conventional irrigation with polypropylene needles (PN), and stainless-steel needles supplemented with manual dynamic agitation using a 0.04 taper standardized cone (MDA-S), manual dynamic agitation with a matched cone (MDA-M), sonic activation with EDDY, or mechanical activation with XP-endo Finisher (XP). Residual hydrogel in the main canal, hydrogel clearance in accessory canals, and irrigant extrusion through the apical vent were assessed. Data were analyzed using two-way analysis of variance with Bonferroni post hoc test (P < .05). RESULTS: In the severe curvature, PN resulted in significantly less residual hydrogel in the main canal than steel needles (P < .05). However, in both curvatures, all supplemental techniques showed superior performance compared with PN (P < .05). MDA-M provided the greatest hydrogel clearance in main and accessory canals (P < .05), but with the highest extrusion (P < .05). CONCLUSION: Polypropylene needles improved apical cleaning in severely curved canals compared with stainless steel needles. However, supplemental activation provided superior overall debridement in both curvatures, although with an increased risk of extrusion.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Eungnapatanin S, Jearanaiphaisarn T, Chivatxaranukul P, et al. Comparative Efficacy and Extrusion Risk of Polypropylene Needle versus Various Supplemental Irrigations in Cleaning Simulated Curved Root Canals. J Endod. 2026. PMID: 41722812. doi:10.1016/j.joen.2026.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。