文献速递牙体牙髓病

超声器械在扁平根管中是否诱发根尖牙本质微裂:microCT与OCT对比分析

Apical Dentin Microcrack Formation After Ultrasonic Instrumentation in Flattened Root Canals: A Comparative Analysis Using Micro-computed Tomography and Optical Coherence Tomography.
PubMed 文献 · J Endod · 2025-12-09

结果显示超声组出现新发微裂,但总体微裂发生率与刷洗组无显著差异;OCT检测可信度高,两种影像技术无显著差异。

要点

  • 超声器械用于扁平根管不显著增加根尖微裂发生率。
  • 刷洗组术后微裂均为术前已存在,超声组可见新发微裂。
  • OCT检测离体牙根尖微裂具有高可靠性。

核心结论

  • 在生物力学预备中加入超声插入器械,与非超声方案相比未显著增加根尖微裂发生率。

研究设计与样本

  • 所有样本先用Reciproc Blue 25/.05和40/.06预备,刷洗组加用40/.06刷洗,超声组用Clearsonic Black超声插入器械处理。
  • 采用microCT和OCT采集处理前后图像并用专用软件分析。

主要发现

  • 处理变量对根尖微裂存在有统计学显著差异(P < .05)。
  • 刷洗组术后识别的根尖微裂均为术前已存在;超声组经microCT识别出新发微裂。
  • 评估者间(P > .05)和所用影像技术间(P > .05)无显著差异。
  • 评估者内和评估者间一致性几乎完美,kappa值为0.858至0.975。

关键数值与推荐

  • 根尖微裂存在按处理变量比较,差异有统计学意义(P < .05)。
  • 评估者内和评估者间kappa值为0.858至0.975。

临床怎么用

  • 扁平根管使用超声插入器械时,无需因根尖微裂风险而完全避免,但应关注新发微裂可能。
  • OCT可作为离体牙根尖微裂检测的可靠方法。

局限性

  • 研究为离体牙实验,样本量每组10颗,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Although ultrasonic inserts are frequently used for the instrumentation of flat root canals, there is a lack of studies investigating whether instrument contact with the canal walls induces the formation of dentinal microcracks. This study aimed to evaluate the formation of apical microcracks, caused by ultrasonic instrumentation, using micro-computed tomography (microCT) and optical coherence tomography (OCT). METHOD: Twenty maxillary second premolars were randomly divided into 2 groups (n = 10): ultrasonic group and brushing group. All specimens were initially prepared using Reciproc Blue files 25/.05 and 40/.06. The brushing group received additional brushing movements with Reciproc Blue 40/.06 and the ultrasonic group underwent instrumentation with a Clearsonic Black ultrasonic insert. Pre- and post-instrumentation images were obtained using both microCT and OCT and were analyzed with specialized software. RESULTS: Statistically significant difference was observed for the treatment variable regarding apical microcrack presence (P < .05). In the brushing group, all apical microcracks identified post-instrumentation were also present preoperatively. In contrast, new incidences were identified in the ultrasonic group via microCT. No significant differences were found for the evaluator (P > .05) or the imaging technique used (P > .05). Intra- and interexaminer agreement was nearly perfect, with kappa values ranging from 0.858 to 0.975. CONCLUSION: The inclusion of an ultrasonic insert during biomechanical preparation did not significantly increase the incidence of apical microcracks when compared with a nonultrasonic protocol. OCT demonstrated high reliability for detecting apical microcracks in extracted teeth.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. de Souza da Silva MP, da Costa Ribeiro A, Bezerra de Oliveira JR, et al. Apical Dentin Microcrack Formation After Ultrasonic Instrumentation in Flattened Root Canals: A Comparative Analysis Using Micro-computed Tomography and Optical Coherence Tomography. J Endod. 2025. PMID: 41380906. doi:10.1016/j.joen.2025.11.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。