Ⅱ型近中根管氢氧化钙与生物陶瓷药物放置及去除的微CT研究
该研究采用微CT比较Ⅱ型近中根管中生物陶瓷药物Bio-C Temp与氢氧化钙药物UltraCal XS的放置和去除效果,发现两组在充填和去除上无显著差异,两种药物均不能完全充填根管,超声活化去除后多数样本仍有残留。
要点
- Bio-C Temp与UltraCal XS在Ⅱ型根管中放置和去除效果相似。
- 两种药物均未完全充填预备根管,去除后多数样本有残留。
- 超声活化去除方案可大幅减少药物体积,但完全清除率低。
核心结论
- UltraCal XS与Bio-C Temp在放置和去除方面结果相似,均不能完全充填预备根管,超声活化去除后多数样本未能完全清除。
研究设计与样本
- 基于微CT评估选取Vertucci Ⅱ型近中根管下颌磨牙,按根管解剖和体积匹配分为2组,使用WaveOne Gold Primary锉预备,分别注入UltraCal XS或Bio-C Temp,15天后用2.5% NaOCl超声活化去除。
主要发现
- 距根尖孔4 mm和8 mm水平,两组药物充填和去除无显著差异(P > .05)。
- 放置后Bio-C Temp充填全根管73%、根尖4 mm段30%,UltraCal XS分别为57%和25%。
- 去除后全根管和根尖段药物体积平均减少:Bio-C Temp为91.9%和88.5%,UltraCal XS为82.6%和81.3%。
- 两组均仅少数样本实现完全清除。
临床怎么用
- 对于Ⅱ型近中根管,两种药物放置和去除效果相当,但均需注意药物无法完全充填和完全清除的问题。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study compared the quality of placement and removal of a bioceramic intracanal medication (Bio-C Temp) and a calcium hydroxide-based medication (UltraCal XS) using micro-computed tomography (micro-CT) analysis. METHODS: Mandibular molars with Vertucci type II mesial root configuration were selected based on micro-CT evaluation. Teeth were allocated into 2 matched groups according to root canal anatomy and volume as similar as possible. Canals were instrumented using WaveOne Gold Primary files. Medications were injected into the canal using a syringe according to the manufacturer's instructions: UltraCal XS (Ultradent, USA) or Bio-C Temp (Angelus, Brazil). After 15 days, the medication was removed by using ultrasonic activation of 2.5% NaOCl. Micro-CT scans were taken after instrumentation, and medication placement and removal to quantify the canal volume and medication volume. RESULTS: No significant differences in medication filling or removal were observed between groups at either the 4-mm or 8-mm canal levels from the apical foramen (P > .05). After placement, Bio-C Temp filled 73% of the full canal length and 30% of the apical 4-mm segment, while UltraCal XS filled 57% and 25%, respectively. The removal protocol substantially reduced medication volumes in both groups, with mean reductions of 91.9% and 88.5% for Bio-C Temp and 82.6% and 81.3% for UltraCal XS in the full canal and apical segments, respectively. Complete elimination was observed in only a few specimens from both groups. CONCLUSION: UltraCal XS and Bio-C Temp exhibited similar results in terms of placement and removal. Neither material completely filled the prepared canal, and removal with ultrasonic activation also failed to achieve complete elimination in most specimens.
引用
- Araya-Cumsille PA, Toloza-Espinoza RA, Brasil SC, et al. Placement and Removal of Calcium Hydroxide and a Bioceramic Medication in Type-II Mesial Molar Canals: A Micro-computed Tomographic Study. J Endod. 2025. PMID: 41429366. doi:10.1016/j.joen.2025.12.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。