两种喷砂大颗粒酸蚀种植体表面的临床与影像学表现:一项分口随机临床试验
本分口随机双中心试验纳入68例受试者(136枚种植体),比较改性亲水表面与常规表面种植体负载后12个月边缘骨水平变化。主要终点无显著组间差异(0.04 mm vs 0.07 mm,p=0.658),软组织愈合、ISQ、种植体周围健康及OHRQoL等次要结局亦无显著差异。
要点
- 改性亲水与常规SLA表面种植体负载后12个月边缘骨变化无显著差异。
- 两组软组织愈合、ISQ、种植体周围健康及OHRQoL均表现相当。
- 两种表面在12个月功能负载期内均安全有效。
核心结论
- 两种喷砂大颗粒酸蚀种植体表面在12个月功能负载期内种植体周围骨稳定性、安全性和临床结局相当。
研究设计与样本
- 随机、分口、双中心临床试验,纳入68例受试者共136枚种植体,每例接受一枚测试(改性亲水表面)和一枚对照(常规表面)种植体。
主要发现
- 负载至12个月边缘骨水平平均变化:改性亲水组0.04 mm(SD=0.39),常规组0.07 mm(SD=0.22),p=0.658。
- 所有测量的临床结局指标均未发现统计学显著组间差异。
- 基线至12个月边缘骨水平变化组间存在小但统计学显著的差异(MD=0.15 mm)。
关键数值与推荐
- 主要终点为负载后12个月边缘骨水平变化,两组间无显著差异(p=0.658)。
- 次要结局包括软组织伤口愈合指数、不良事件、种植体稳定性商、种植体周围软组织参数及OHIP-14量表评估的口腔健康相关生活质量,均无显著组间差异。
临床怎么用
- 两种SLA表面种植体在12个月观察期内均可安全用于临床,骨稳定性与软组织结局相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To compare the clinical performance of two sandblasted, large-grit, acid-etched implant surfaces regarding changes in radiographic marginal bone level (MBL) 12 months after loading. MATERIALS AND METHODS: In this randomized, split-mouth, dual-center clinical trial, each patient received one test (modified hydrophilic surface) implant and one control (conventional surface) implant. The primary endpoint was the change in MBL measured 12 months after loading. Secondary outcomes included the assessment of soft tissue wound healing index (WHI), adverse events, implant stability quotient (ISQ), peri-implant soft tissue parameters (probing pocket depth, bleeding on probing, keratinized mucosa width), and oral health-related quality of life (OHRQoL) measured with the Oral Health Impact Profile-14 (OHIP-14). Generalized linear models, paired Student's t-tests, and Wilcoxon tests were employed for data analysis. RESULTS: The study included 68 subjects (136 implants). No statistically significant differences were found between groups for any of the clinical outcomes measured. The mean change in MBL from loading to 12 months was 0.04 mm (SD = 0.39) for the modified hydrophilic implants and 0.07 mm (SD = 0.22) for the conventional implants (p = 0.658), with no significant differences between the groups. CONCLUSIONS: Over a 12-month period of functional loading, both implant surfaces demonstrated comparable performance regarding peri-implant bone stability, safety, and clinical outcomes. Although a small but statistically significant difference between groups was observed in MBL changes from baseline to 12 months (MD = 0.15 mm), no significant differences were found in MBL changes from loading to 12 months (primary outcome), ISQ, soft tissue healing, or peri-implant health.
引用
- Vílchez B, Caneiro L, Lima C, et al. Clinical and Radiographic Performance of Two Distinct Sandblasted, Large-Grit, Acid-Etched Implant Surfaces: A Split-Mouth Randomized Clinical Trial. Clin Oral Implants Res. 2025. PMID: 41199413. doi:10.1111/clr.70071
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。