文献速递牙体牙髓病

机器人与动态导航系统在纤维桩拆除中的效果比较:一项体外研究

Comparing the Effectiveness of a Robotic and Dynamic Navigation System in Fiber Post removal: An In Vitro Study.
PubMed 文献 · J Endod · 2025-10-24

结果显示RS组根尖偏差、角度偏转和操作时间均最低,DNS次之,FH最差,提示RS在体外模型中具有更高的精度和效率。

要点

  • RS组根尖偏差、角度偏转和操作时间均显著低于DNS和FH组。
  • 冠部偏差三组间无显著差异。
  • 该结论基于3D打印牙体外模型,需临床进一步验证。

核心结论

  • 在3D打印牙体外模型中,机器人系统拆除纤维桩的精度和效率优于动态导航系统和徒手技术。

主要发现

  • RS组根尖偏差(0.23 ± 0.04 mm)、角度偏转(0.94° ± 0.33°)和操作时间(0.81 ± 0.07 min)最低,DNS组分别为0.50 ± 0.13 mm、2.43° ± 0.82°、2.17 ± 0.70 min,FH组最高分别为0.92 ± 0.27 mm、4.84° ± 1.67°、3.64 ± 1.25 min(P < .05)。
  • 冠部偏差三组间无显著差异(P > .05)。

临床怎么用

  • 在体外条件下,机器人系统可能提高纤维桩拆除的精度和效率,但临床适用性需进一步研究。

局限性

  • 研究为体外设计,使用3D打印牙模型,结果不能直接推广至临床。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This in vitro study evaluated the effectiveness of a robotic system (RS) and dynamic navigation system (DNS) compared with the freehand technique (FH) in fiber post removal. METHODS: Thirty-six 3D-printed teeth were fabricated from a human extracted maxillary incisor that had undergone root canal treatment and postspace preparation. After fiber post cementation, the 3D-printed replicas were mounted in plaster models and randomly assigned to RS, DNS, and FH groups (n = 12 each). Cone-beam computed tomography and model scans were performed on all models. The drilling trajectory was planned virtually using DentalNavi software. Fiber postremoval was performed by a single experienced endodontist using DNS, RS, or FH under a dental operating microscope, with operation time recorded. Pre- and post instrumentation data were obtained using micro-computed tomography. Coronal deviation, apical deviation, angular deflection, and operation time were compared among groups using One-way ANOVA and least significant difference tests. RESULTS: There were no significant differences in coronal deviation (P > .05). The RS group showed the lowest apical deviation (0.23 ± 0.04 mm), angular deflection (0.94° ± 0.33°), and shortest operation time (0.81 ± 0.07 min), followed by the DNS group (0.50 ± 0.13 mm, 2.43° ± 0.82°, 2.17 ± 0.70 min). FH had the greatest deviations and longest time (0.92 ± 0.27 mm, 4.84° ± 1.67°, 3.64 ± 1.25 min) (P < .05). CONCLUSIONS: In this benchtop in vitro study using 3D-printed teeth, the RS demonstrated superior accuracy and efficiency in fiber post removal compared with DNS and FH technique.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Zhou D, Xu F, Dai J, et al. Comparing the Effectiveness of a Robotic and Dynamic Navigation System in Fiber Post removal: An In Vitro Study. J Endod. 2025. PMID: 41236008. doi:10.1016/j.joen.2025.10.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。