引导牙髓治疗中配准策略的配准精度研究
本研究利用3D打印下颌骨模型,评估不同配准策略(基准标记数量、配置和分布范围)对动态导航系统引导根管治疗配准精度的影响。结果显示,4个标记的靶区配准误差显著低于3个,四边形配置误差显著低于线性和三角形配置,且前牙目标牙及邻牙区域标记误差显著低于下颌牙列区域。结论为选择目标牙周围4个空间四边形基准标记可获得最佳配准精度。
要点
- 4个基准标记的配准精度显著优于3个,增加至10个未进一步降低误差。
- 四边形配置的靶区配准误差显著低于线性和三角形配置。
- 前牙目标牙及邻牙区域标记的误差显著低于下颌牙列区域。
核心结论
- 在牙髓治疗中,选择目标牙周围4个空间四边形基准标记可获得最佳配准精度。
主要发现
- 4个标记的TRE显著低于3个标记,前牙为0.32 mm vs 0.62 mm(P < .05),后牙为0.22 mm vs 1.43 mm(P < .05)。
- 标记数量增加至10个未进一步降低TRE(P > .05)。
- 四边形配置标记的TRE显著低于线性和三角形配置(P < .05)。
- 前牙目标牙和邻牙区域所选标记的TRE显著低于下颌牙列区域(P < .05)。
临床怎么用
- 临床进行引导牙髓治疗配准时,建议在目标牙周围放置4个呈空间四边形分布的基准标记,以优化配准精度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The objective of this study was to evaluate which registration strategy (the number, configuration, and distribution range of fiducial markers) could obtain the optimal registration accuracy for guided root canal therapy. METHODS: One 3-dimensional-printed mandibular jaw model was created. The fiducial markers used for registration were prepared on the crowns of anterior and posterior teeth. The models were scanned using cone-beam computed tomography, and digital models were built. Different numbers (3, 4, 6, 8, and 10), configurations (quadrilateral, triangular, and linear) and distribution ranges (target tooth, adjacent teeth, and mandibular dentition) of fiducial markers were applied for registration of the dynamic navigation system. The target registration error (TRE) was measured. One-way analysis of variance was applied to assess registration error between groups. The significance level was set at .05. RESULTS: The TREs of 4 markers were significantly lower than those of three for both anterior tooth (0.32 mm vs 0.62 mm; P < .05) and posterior tooth (0.22 mm vs 1.43 mm; P < .05); increasing the number of markers to ten did not further reduce the TREs (P > .05). The TREs of markers arranged in a quadrilateral configuration were significantly lower than those in linear and triangular configurations (P < .05). The TREs of the markers selected on the target tooth and adjacent teeth were significantly lower than those in the mandibular dentition region for anterior tooth (P < .05). CONCLUSIONS: In endodontic treatment, the best registration accuracy was obtained by selecting four spatial quadrilateral fiducial markers localized around the target tooth.
引用
- Liu C, Ma L, Zhang Y, et al. Research on Registration Strategy for Guided Endodontics. J Endod. 2025. PMID: 41205993. doi:10.1016/j.joen.2025.10.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。